OSHA SearchOSHA records by employer

The Sausage Kitchen Inc: OSHA inspections and violations

Milwaukie, Oregon · Meat Processed from Carcasses · NAICS 311612

4inspections
12citation items
$775current penalties
Oct 12, 2018last inspection

OSHA has inspected The Sausage Kitchen Inc 4 times in Oregon since 2010.

The latest one began on Oct 12, 2018 as a planned inspection, in Milwaukie.

Those inspections ended with 12 citation items: 6 serious and 6 other-than-serious.

Penalties were first proposed at $775 and still stand at $775.

Grounding and circuit protection comes up most often in these citations: 2 items under 1910.304.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,875, and The Sausage Kitchen Inc averages $60 (2 cited inspections).

The Sausage Kitchen Inc: OSHA citation items per year, 2010 to 2018
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

391employers cited

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch The Sausage Kitchen Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343532529 OPENED OCT 12, 2018Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jun 5, 2019

18893 Se Mcloughlin Blvd, Milwaukie, OR 97267 · Meat Processed from Carcasses · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-001-0765(13)-1
Other-than-serious$0$0Feb 13, 2019Final

Inspection 340723071 OPENED MAY 12, 2015Closed

Planned · Complete · Safety · 5 employees at the site · Closed Dec 21, 2016

18893 Se Mcloughlin Blvd, Milwaukie, OR 97267 · Meat Processed from Carcasses · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(b)(2)(ii) · Grounding and circuit protection
Serious$120$120Jun 24, 2015Final
Citation 2, item 2
29 CFR OAR 437-002-0041(11)(B)
Other-than-serious$0$0Jun 24, 2015Final

Inspection 314969239 OPENED NOV 1, 2010Closed

Referral · Partial · Health · 6 employees at the site · Closed Feb 17, 2011

18893 Se Mcloughlin Blvd, Milwaukie, OR 97267 · Meat Processed from Carcasses · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$165$165Nov 18, 2010Closed

Inspection 314967563 OPENED OCT 6, 2010Closed

Planned · Complete · Safety · 6 employees at the site · Closed Feb 17, 2011

18893 Se Mcloughlin Blvd, Milwaukie, OR 97267 · Meat Processed from Carcasses · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$100$100Nov 18, 2010Closed
Citation 1, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$165$165Nov 18, 2010Closed
Citation 1, item 3 Serious$125$125Nov 18, 2010Closed
Citation 1, item 4
29 CFR 1910.304(g)(6)(vic)(1) · Grounding and circuit protection
Serious$100$100Nov 18, 2010Closed
Citation 2, item 5 Other-than-serious$0$0Nov 18, 2010Closed
Citation 2, item 6
29 CFR 1910.305(g)(1)(iva) · Electrical wiring methods
Other-than-serious$0$0Nov 18, 2010Closed
Citation 2, item 7
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Nov 18, 2010Closed
Citation 2, item 8 Other-than-serious$0$0Nov 18, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.304(b)(2)(ii)

(ii) Receptacles and cord connectors having grounding contacts shall have those contacts effectively grounded except for receptacles mounted on portable and vehicle-mounted generators in accordance with paragraph (g)(3) of this section and replacement receptacles installed in accordance with paragraph (b)(2)(iv) of this section.

29 CFR 1910.304(g)(6)(vic)(1)

(C) If the equipment is of the following types:

29 CFR 1910.305 · Electrical wiring methods

29 CFR 7010.7600

29 CFR 7010.7650

29 CFR 7020.1610

29 CFR 7020.260

29 CFR 7020.3780

Other meat processed from carcasses employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.