OSHA SearchOSHA records by employer

The Zelco Group, LLC: OSHA inspections and violations

West Haven, Connecticut · Residential Remodelers · NAICS 236118

1inspections
7citation items
$7,000current penalties
Apr 19, 2017last inspection

The Zelco Group, LLC has one OSHA inspection on record in Connecticut.

OSHA opened it on Apr 19, 2017 on a referral, in West Haven.

From that inspection OSHA issued 7 citation items: 7 serious.

OSHA proposed $10,321 in penalties. After settlements and reviews the total is $7,000, down 32%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. The Zelco Group, LLC averages $7,000 over 1 cited inspection in that time.

The Zelco Group, LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

86employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch The Zelco Group, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342354784 OPENED APR 19, 2017Closed

Referral · Partial · Safety · 9 employees at the site · Closed Feb 25, 2019

100 Laurel Street, West Haven, CT 06516 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,716$1,850Jun 9, 2017Final
Citation 1, item 1b
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$0$0Jun 9, 2017Final
Citation 1, item 2
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$2,716$1,850Jun 9, 2017Final
Citation 1, item 3a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,716$1,850Jun 9, 2017Final
Citation 1, item 3b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Jun 9, 2017Final
Citation 1, item 4a
29 CFR 1926.454(a)(1) · Scaffold training
Serious$2,173$1,450Jun 9, 2017Final
Citation 1, item 4b
29 CFR 1926.454(b)(1) · Scaffold training
Serious$0$0Jun 9, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other residential remodelers employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.