OSHA SearchOSHA records by employer

Therm-O-Link dba Vulkor Inc.: OSHA inspections and violations

Warren, Ohio · Steel Wire Drawing · NAICS 331222

1inspections
3citation items
$11,410current penalties
Dec 17, 2015last inspection

OSHA inspectors have visited Therm-O-Link dba Vulkor Inc. in Ohio one time.

It opened on Dec 17, 2015 after a complaint, in Warren.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $20,300; today they stand at $11,410, 44% less.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Therm-O-Link dba Vulkor Inc. averages $11,410 across 1 cited inspection.

Therm-O-Link dba Vulkor Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

257employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Therm-O-Link dba Vulkor Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341139640 OPENED DEC 17, 2015Closed

Complaint · Partial · Health · 41 employees at the site · Closed Aug 29, 2016

621 Dana St. Ne Ste. #5, Warren, OH 44483 · Steel Wire Drawing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$3,600$2,520Feb 11, 2016Final
Citation 1, item 2
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$2,700$1,890Feb 11, 2016Final
Citation 2, item 1
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$14,000$7,000Feb 11, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(d)(1)

(d) Pulleys—(1) Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(1)(iv)(a)

(A) As a substitute for the fixed wiring of a structure;

Other steel wire drawing employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.