OSHA SearchOSHA records by employer

Thielen Turf Irrigation, Inc.: OSHA inspections and violations

Mount Pleasant, Michigan · Site Preparation Contractors · NAICS 238910

5inspections
24citation items
$2,300current penalties
Aug 15, 2018last inspection

Thielen Turf Irrigation, Inc. has 5 OSHA inspections on record in Michigan, the first in 1991.

OSHA's last visit started on Aug 15, 2018 as a planned inspection, in Grand Rapids.

Across those inspections OSHA issued 24 citation items: 7 serious and 17 other-than-serious.

OSHA proposed $4,200 in penalties. After settlements and reviews the total is $2,300, down 45%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Thielen Turf Irrigation, Inc. averages $400 over 1 cited inspection in that time.

Thielen Turf Irrigation, Inc. also files yearly injury logs with OSHA, summarized below.

Thielen Turf Irrigation, Inc.: OSHA citation items per year, 1991 to 2018
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

641employers cited

35 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Thielen Turf Irrigation, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343385654 OPENED AUG 15, 2018Closed

Planned · Complete · Safety · 4 employees at the site · Closed Oct 18, 2018

3725 Cascade Road Se, Grand Rapids, MI 49546 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.41721
Serious$400$400Sep 27, 2018Final
Citation 2, item 1
29 CFR 408.40132(3)
Other-than-serious$0$0Sep 27, 2018Final
Citation 2, item 2
29 CFR 408.40933(2)
Other-than-serious$0$0Sep 27, 2018Final
Citation 2, item 3
29 CFR 408.41523(1)
Other-than-serious$0$0Sep 27, 2018Final

Inspection 304896293 OPENED OCT 10, 2002Closed

Planned · Complete · Safety · 5 employees at the site · Closed Oct 10, 2002

3117 Elias Rd, Beal City, MI 48855 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 127134690 OPENED JUL 2, 2001Closed

Planned · Complete · Safety · 49 employees at the site · Closed Sep 18, 2001

600 Industrial Ave, Mt Pleasant, MI 48858 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$600$300Aug 10, 2001Closed
Citation 1, item 2 Serious$600$300Aug 10, 2001Closed
Citation 1, item 3 Serious$600$300Aug 10, 2001Closed
Citation 1, item 4 Serious$600$300Aug 10, 2001Closed
Citation 1, item 5
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$800$400Aug 10, 2001Closed
Citation 1, item 6
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$600$300Aug 10, 2001Closed
Citation 2, item 1 Other-than-serious$0$0Aug 10, 2001Closed
Citation 2, item 2 Other-than-serious$0$0Aug 10, 2001Closed
Citation 2, item 3 Other-than-serious$0$0Aug 10, 2001Closed
Citation 2, item 4 Other-than-serious$0$0Aug 10, 2001Closed
Citation 2, item 5 Other-than-serious$0$0Aug 10, 2001Closed
Citation 2, item 6 Other-than-serious$0$0Aug 10, 2001Closed
Citation 2, item 7 Other-than-serious$0$0Aug 10, 2001Closed
Citation 2, item 8 Other-than-serious$0$0Aug 10, 2001Closed
Citation 2, item 9 Other-than-serious$0$0Aug 10, 2001Closed
Citation 2, item 10 Other-than-serious$0$0Aug 4, 2001Closed
Citation 2, item 11 Other-than-serious$0$0Aug 10, 2001Closed
Citation 2, item 12 Other-than-serious$0$0Aug 10, 2001Closed
Citation 2, item 13
29 CFR 1910.169(b)(3)(i) · Air receivers
Other-than-serious$0$0Aug 10, 2001Closed
Citation 2, item 14 Other-than-serious$0$0Aug 10, 2001Closed

Inspection 124840695 OPENED MAY 3, 1996Closed

Planned · Complete · Safety · 4 employees at the site · Closed May 7, 1996

15101 Chandler, Bath, MI 48808 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 114685175 OPENED JUN 5, 1991Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jun 6, 1991

Across From 6506 E Airport Rd, Mount Pleasant, MI 48858 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the Mount Pleasant site logged 0 recordable injuries or illnesses among about 34 workers: 0.0 per 100 full-time workers, against a median of 3.0 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Thielen Turf
Mount Pleasant · 2017
34 000.03.0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.169 · Air receivers

29 CFR 1910.169(b)(3)(i)

(3) Gages and valves. (i) Every air receiver shall be equipped with an indicating pressure gage (so located as to be readily visible) and with one or more spring-loaded safety valves. The total relieving capacity of such safety valves shall be such as to prevent pressure in the receiver from exceeding the maximum allowable working pressure of the receiver by more than 10 percent.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(2)(i)

(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:

29 CFR 4081.1115

29 CFR 4081.125

29 CFR 4081.213

29 CFR 4081.2154

29 CFR 4081.221

29 CFR 4081.2219

29 CFR 4081.2234

29 CFR 4081.3308

29 CFR 4081.3881

29 CFR 4081.4923

29 CFR 4081.4925

29 CFR 4081.632

29 CFR 4081.685

29 CFR 4081.716

29 CFR 4081.7211

29 CFR 4081.727

29 CFR 4082.2111

Other site preparation contractors employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.