OSHA SearchOSHA records by employer

Three Brothers Contracting LLC: OSHA inspections and violations

Oakland, Florida · Framing Contractors · NAICS 238130

1inspections
7citation items
$6,866current penalties
Jan 22, 2026last inspection

Three Brothers Contracting LLC has one OSHA inspection on record in Florida.

OSHA opened it on Jan 22, 2026 as a planned inspection, in Oakland, and the case has not closed yet.

From that inspection OSHA issued 7 citation items: 7 serious.

OSHA proposed $12,484 in penalties. After settlements and reviews the total is $6,866, down 45%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Three Brothers Contracting LLC averages $6,866 over 1 cited inspection in that time.

Three Brothers Contracting LLC: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

41 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Three Brothers Contracting LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348701848 OPENED JAN 22, 2026Open

Planned · Partial · Safety · 5 employees at the site · Open

1191 Riverway, Oakland, FL 34787 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,270$1,248Jan 29, 2026Final
Citation 1, item 2a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$3,972$2,185Jan 29, 2026Final
Citation 1, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Jan 29, 2026Final
Citation 1, item 2c
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$0$0Jan 29, 2026Final
Citation 1, item 2d
29 CFR 1926.452(k)(5) · Rules for each type of scaffold
Serious$0$0Jan 29, 2026Final
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,972$2,185Jan 29, 2026Final
Citation 1, item 4
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$2,270$1,248Jan 29, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.