OSHA SearchOSHA records by employer

Three Brothers Roofing: OSHA inspections and violations

Flushing, New York · Roofing Contractors · NAICS 238160

4inspections
10citation items
$8,723current penalties
Aug 25, 2022last inspection

Since 1991, OSHA inspectors have visited Three Brothers Roofing in New York 4 times.

The most recent inspection opened on Aug 25, 2022, in Hudson Falls and is still open.

In all, OSHA issued 10 citation items: 7 serious and 3 other-than-serious.

The penalties, $8,723 in total, stand where OSHA first set them.

The rule cited most here is 1926.1053 (ladders in construction), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Three Brothers Roofing averages $6,698 across 1 cited inspection.

Three Brothers Roofing: OSHA citation items per year, 1991 to 2022
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

57 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Three Brothers Roofing and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346174717 OPENED AUG 25, 2022Open

Programmed other · Partial · Safety · 3 employees at the site · Open

35 Notre Dame St, Hudson Falls, NY 12839 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,349$3,349Jan 25, 2023Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,349$3,349Jan 25, 2023Final

Inspection 108656224 OPENED FEB 3, 1993Closed

Unprogrammed related · Complete · Safety · 12 employees at the site · Closed Mar 3, 1995

Trailer 21, Grvc Shore Road, Rikers Island, E. Elmhurst, NY 11370 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$375$375May 20, 1993Closed
Citation 1, item 2
29 CFR 1926.500(g)(1) · Scope, application, and definitions applicable to this subpart
Serious$525$525May 20, 1993Closed
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$300$300May 20, 1993Closed
Citation 1, item 4
29 CFR 1926.1053(b)(8) · Ladders in construction
Serious$300$300May 20, 1993Closed

Inspection 108941808 OPENED MAR 6, 1992Closed

Follow-up · Partial · Safety · 10 employees at the site · Closed Mar 11, 1992

P.o. Box 455 Hanger #6, Laguardia Airport, Flushing, NY 11371 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 106752751 OPENED NOV 25, 1991Closed

Unprogrammed related · Complete · Safety · 7 employees at the site · Closed Mar 11, 1992

P.o. Box 455 Hanger #6, Laguardia Airport, Flushing, NY 11371 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$525$525Dec 18, 1991Closed
Citation 2, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Dec 18, 1991Closed
Citation 2, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Dec 18, 1991Closed
Citation 2, item 3
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Dec 18, 1991Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(8)

(8) Ladders placed in any location where they can be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, shall be secured to prevent accidental displacement, or a barricade shall be used to keep the activities or traffic away from the ladder.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.59 · Hazard communication

Other roofing contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.