OSHA SearchOSHA records by employer

Tica General Construction Inc.: OSHA inspections and violations

Staten Island, New York · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
2citation items
$5,600current penalties
Aug 28, 2015last inspection

Tica General Construction Inc. has one OSHA inspection on record in New York.

OSHA opened it on Aug 28, 2015 on a referral, in Staten Island.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $5,600 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Tica General Construction Inc. averages $5,600 over 1 cited inspection in that time.

Tica General Construction Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Tica General Construction Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340884303 OPENED AUG 28, 2015Closed

Referral · Partial · Safety · 4 employees at the site · Closed Jan 30, 2017

151 Van Pelt Ave, Staten Island, NY 10303 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.850(a) · Preparatory operations
Serious$2,800$2,800Dec 30, 2015Final
Citation 1, item 2
29 CFR 1926.854(d) · Removal of walls, masonry sections, and chimneys
Serious$2,800$2,800Dec 30, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.850 · Preparatory operations

29 CFR 1926.850(a)

(a) Prior to permitting employees to start demolition operations, an engineering survey shall be made, by a competent person, of the structure to determine the condition of the framing, floors, and walls, and possibility of unplanned collapse of any portion of the structure. Any adjacent structure where employees may be exposed shall also be similarly checked. The employer shall have in writing evidence that such a survey has been performed.

29 CFR 1926.854 · Removal of walls, masonry sections, and chimneys

29 CFR 1926.854(d)

(d) Structural or load-supporting members on any floor shall not be cut or removed until all stories above such a floor have been demolished and removed. This provision shall not prohibit the cutting of floor beams for the disposal of materials or for the installation of equipment, provided that the requirements of §§ 1926.853 and 1926.855 are met.

Other new single-family housing construction (except for-sale builders) employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.