Inspection 344487947 OPENED DEC 4, 2019Closed
980 Westsprings Dr, Eugene, OR 97402 · Siding Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected TJ Siding LLC 8 times in Oregon since 2007.
The latest one began on Dec 4, 2019 as a planned inspection, in Eugene.
Those inspections ended with 11 citation items: 8 serious and 3 other-than-serious.
Penalties were first proposed at $2,285 and still stand at $2,285.
Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and TJ Siding LLC averages $450 (1 cited inspection).
Oregon · latest 90 days of OSHA records
388employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Oregon
Checking a subcontractor, a client or your own company? Watch TJ Siding LLC and get notified the morning OSHA posts a new citation for it.
Watch this company980 Westsprings Dr, Eugene, OR 97402 · Siding Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2940 Crescent Ave, Eugene, OR 97408 · Siding Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.502(d)(15)(ii) · Fall protection systems |
Serious | $350 | $350 | May 3, 2018 | Final |
| Citation 1, item 2 29 CFR OAR 437-002-0134(8)(A) |
Serious | $100 | $100 | May 3, 2018 | Final |
1739 Ferry St, Eugene, OR 97402 · Siding Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $210 | $210 | Feb 14, 2013 | Closed |
| Citation 2, item 2 | Other-than-serious | $0 | $0 | Feb 14, 2013 | Closed |
338 Hwy 99 N, Eugene, OR 97402 · Siding Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $375 | $375 | Jan 22, 2010 | Closed |
| Citation 1, item 2 | Serious | $375 | $375 | Jan 22, 2010 | Closed |
| Citation 1, item 3 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $375 | $375 | Jan 22, 2010 | Closed |
95603 Marcola Rd, Marcola, OR 97454 · Siding Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1762 Hilyard St, Eugene, OR 97401 · Siding Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $125 | $125 | Jul 16, 2008 | Closed |
| Citation 2, item 2 29 CFR 1926.1060(a) · Ladder and stairway training |
Other-than-serious | $0 | $0 | Jul 16, 2008 | Closed |
1762 Hilyard St, Eugene, OR 97401 · Siding Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.59(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 29, 2008 | Closed |
3370 Murry Dr, Eugene, OR 97405 · Siding Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 7031501 |
Serious | $375 | $375 | Aug 30, 2007 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.1060(a)
(a) The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards.
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.