OSHA SearchOSHA records by employer

TJC Construction, Inc: OSHA inspections and violations

Vega Baja, Puerto Rico · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

4inspections
19citation items
$5,688current penalties
May 22, 2015last inspection

TJC Construction, Inc has 4 OSHA inspections on record in Puerto Rico, the first in 2003.

OSHA's last visit started on May 22, 2015 as a planned inspection, in San Juan.

Across those inspections OSHA issued 19 citation items: 12 serious and 7 other-than-serious.

OSHA proposed $15,850 in penalties. After settlements and reviews the total is $5,688, down 64%.

Most often, OSHA cited 1926.1060, ladder and stairway training (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. TJC Construction, Inc averages $600 over 1 cited inspection in that time.

TJC Construction, Inc: OSHA citation items per year, 2003 to 2015
Citation items per year, by inspection date.

Puerto Rico · latest 90 days of OSHA records

113employers cited

Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Puerto Rico

Checking a subcontractor, a client or your own company? Watch TJC Construction, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340652346 OPENED MAY 22, 2015Closed

Planned · Complete · Safety · 6 employees at the site · Closed Oct 19, 2023

Esq San San Jose 106 Calle Luna, San Juan, PR 00919 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$600$600Nov 30, 2015Final
Citation 2, item 1
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Other-than-serious$0$0Nov 30, 2015Final

Inspection 305830689 OPENED FEB 22, 2006Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed May 4, 2006

Carr 687 Km 0.7 Bo Torutguero Pisos Reales, Vega Baja, PR 00693 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,000$1,000Apr 18, 2006Closed
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Other-than-serious$2,000$0Apr 18, 2006Closed

Inspection 305829020 OPENED MAY 5, 2005Closed

Planned · Complete · Safety · 25 employees at the site · Closed Jul 29, 2005

Carr 687 Km 0.7 Bo Torutguero Pisos Reales, Vega Baja, PR 00693 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,500$750Jun 20, 2005Closed
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$750Jun 20, 2005Closed
Citation 1, item 3
29 CFR 1926.454(a) · Scaffold training
Other-than-serious$1,500$200Jun 20, 2005Closed
Citation 1, item 4
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,100$1,050Jun 20, 2005Closed
Citation 1, item 5
29 CFR 1926.503(a)(1) · Fall protection training in construction
Other-than-serious$525$150Jun 20, 2005Closed
Citation 1, item 6
29 CFR 1926.1052(b)(1) · Stairways in construction
Other-than-serious$1,500$200Jun 20, 2005Closed
Citation 1, item 7a
29 CFR 1926.1060(a)(1)(i) · Ladder and stairway training
Other-than-serious$1,500$200Jun 20, 2005Closed
Citation 1, item 7b
29 CFR 1926.1060(a)(1)(ii) · Ladder and stairway training
Serious$0$0Jun 20, 2005Closed
Citation 1, item 7c
29 CFR 1926.1060(a)(1)(iii) · Ladder and stairway training
Serious$0$0Jun 20, 2005Closed
Citation 1, item 7d
29 CFR 1926.1060(a)(1)(iv) · Ladder and stairway training
Serious$0$0Jun 20, 2005Closed
Citation 1, item 7e
29 CFR 1926.1060(a)(1)(v) · Ladder and stairway training
Serious$0$0Jun 20, 2005Closed

Inspection 305955023 OPENED FEB 20, 2003Closed

Unprogrammed other · Complete · Safety · 20 employees at the site · Closed Apr 10, 2003

Carr 31 Km 21.3, Juncos, PR 00777 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$525$368Mar 20, 2003Closed
Citation 1, item 2
29 CFR 1926.550(a)(6) · [Reserved]
Serious$225$158Mar 20, 2003Closed
Citation 1, item 3 Serious$225$158Mar 20, 2003Closed
Citation 2, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$150$105Mar 20, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(b)(1)

(1) Except during stairway construction, foot traffic is prohibited on stairways with pan stairs where the treads and/or landings are to be filled in with concrete or other material at a later date, unless the stairs are temporarily fitted with wood or other solid material at least to the top edge of each pan. Such temporary treads and landings shall be replaced when worn below the level of the top edge of the pan.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1060(a)(1)(i)

(i) The nature of fall hazards in the work area;

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.550 · [Reserved]

Other new single-family housing construction (except for-sale builders) employers in Puerto Rico

Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.