OSHA SearchOSHA records by employer

TM Smith Tool International Corporation: OSHA inspections and violations

Mount Clemens, Michigan · Cutting Tool and Machine Tool Accessory Manufacturing · NAICS 333515

1inspections
15citation items
$3,000current penalties
Jun 27, 2018last inspection

TM Smith Tool International Corporation has one OSHA inspection on record in Michigan.

OSHA opened it on Jun 27, 2018 as a planned inspection, in Mount Clemens.

From that inspection OSHA issued 15 citation items: 7 serious and 8 other-than-serious.

OSHA proposed $8,100 in penalties. After settlements and reviews the total is $3,000, down 63%.

Most often, OSHA cited 1910.147, lockout/tagout (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. TM Smith Tool International Corporation averages $3,000 over 1 cited inspection in that time.

TM Smith Tool International Corporation: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

609employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch TM Smith Tool International Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343256244 OPENED JUN 27, 2018Closed

Planned · Complete · Safety · 27 employees at the site · Closed Nov 1, 2018

360 Hubbard St, Mount Clemens, MI 48043 · Cutting Tool and Machine Tool Accessory Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 408.10123
Serious$900$450Sep 7, 2018Final
Citation 1, item 1b
29 CFR 408.10187(1)
Serious$900$0Sep 7, 2018Final
Citation 1, item 3
29 CFR 408.10731(1)
Serious$900$450Sep 7, 2018Final
Citation 1, item 4a
29 CFR 408.11115(1)
Serious$1,200$600Sep 7, 2018Final
Citation 1, item 4b
29 CFR 408.11115(4)
Serious$1,200$0Sep 7, 2018Final
Citation 1, item 6
29 CFR 408.12154(1)
Serious$1,500$750Sep 7, 2018Final
Citation 1, item 7
29 CFR 408.13350
Serious$1,500$750Sep 7, 2018Final
Citation 2, item 1a
29 CFR 408.1014K(1)
Other-than-serious$0$0Sep 7, 2018Final
Citation 2, item 1b
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Sep 7, 2018Final
Citation 2, item 1c
29 CFR 1910.1200(h)(3) · Hazard communication
Other-than-serious$0$0Sep 7, 2018Final
Citation 2, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Sep 7, 2018Final
Citation 2, item 3a
29 CFR 1910.106(e)(2)(iv)(d) · Flammable liquids
Other-than-serious$0$0Sep 7, 2018Final
Citation 2, item 3b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Other-than-serious$0$0Sep 7, 2018Final
Citation 2, item 4a
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Sep 7, 2018Final
Citation 2, item 4b
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Sep 7, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(iv)(d)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(g)(8)

(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.305 · Electrical wiring methods

Other cutting tool and machine tool accessory manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.