OSHA SearchOSHA records by employer

Tmac Constructions: OSHA inspections and violations

Philadelphia, Pennsylvania · Masonry Contractors · NAICS 238140

2inspections
9citation items
$31,269current penalties
Apr 22, 2025last inspection

Tmac Constructions has 2 OSHA inspections on record in Pennsylvania, the first in 2017.

OSHA's last visit started on Apr 22, 2025 on a referral, in Philadelphia, and the case has not closed yet.

Across those inspections OSHA issued 9 citation items: 9 serious.

OSHA proposed $31,269 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (6 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,078. Tmac Constructions averages $15,634 over 2 cited inspections in that time.

Tmac Constructions: OSHA citation items per year, 2017 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Tmac Constructions again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348197104 OPENED APR 22, 2025Open

Referral · Partial · Safety · 2 employees at the site · Open

1388 S 10th Street, Philadelphia, PA 19147 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,972$3,972Aug 22, 2025Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,972$3,972Aug 22, 2025Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,972$3,972Aug 22, 2025Final
Citation 1, item 4
29 CFR 1926.454(a) · Scaffold training
Serious$3,972$3,972Aug 22, 2025Final
Citation 1, item 5
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$3,972$3,972Aug 22, 2025Final

Inspection 342824000 OPENED JUN 27, 2017Closed

Referral · Partial · Safety · 3 employees at the site · Closed Aug 23, 2023

631 Mckean Street, Philadelphia, PA 19148 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(3) · Scaffolds, general requirements
Serious$3,803$3,803Dec 20, 2017Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,803$3,803Dec 20, 2017Final
Citation 1, item 3a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,803$3,803Dec 20, 2017Final
Citation 1, item 3b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Dec 20, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(3)

(3) Except as provided in paragraphs (b)(3) (i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling.

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Pennsylvania

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.