OSHA SearchOSHA records by employer

TNT Masonry: OSHA inspections and violations

Flower Mound, Texas · Masonry Contractors · NAICS 238140

1inspections
3citation items
$5,742current penalties
Mar 15, 2021last inspection

TNT Masonry has one OSHA inspection on record in Texas.

OSHA opened it on Mar 15, 2021 as a planned inspection, in Flower Mound.

From that inspection OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $5,742 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. TNT Masonry averages $5,742 over 1 cited inspection in that time.

TNT Masonry: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites TNT Masonry again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345196281 OPENED MAR 15, 2021Closed

Planned · Partial · Safety · 10 employees at the site · Closed Sep 20, 2023

1551 Justin Rd., Flower Mound, TX 75028 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,926$2,926Mar 26, 2021Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,487$2,487Mar 26, 2021Final
Citation 2, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Other-than-serious$329$329Mar 26, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

Other masonry contractors employers in Texas