OSHA SearchOSHA records by employer

Tomas Godines: OSHA inspections and violations

Grand Prairie, Texas · Masonry Contractors · NAICS 238140

1inspections
6citation items
$4,308current penalties
Mar 20, 2026last inspection

OSHA inspectors have visited Tomas Godines in Texas one time.

It opened on Mar 20, 2026 as a planned inspection, in Grand Prairie and is still open.

In all, OSHA issued 6 citation items: 6 serious.

The proposed penalties came to $14,188; today they stand at $4,308, 70% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Tomas Godines averages $4,308 across 1 cited inspection.

Tomas Godines: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

398employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Tomas Godines and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348829615 OPENED MAR 20, 2026Open

Planned · Partial · Safety · 4 employees at the site · Open

3681 Saquaro Drive, Grand Prairie, TX 75052 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.100(a) · Hard hats in construction
Serious$3,405$1,077Aug 31, 2026Final
Citation 1, item 1b
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,270$0Aug 31, 2026Final
Citation 1, item 2
29 CFR 1926.304(d) · Woodworking tools
Serious$2,838$1,077Aug 31, 2026Final
Citation 1, item 3
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$2,270$1,077Aug 31, 2026Final
Citation 1, item 4a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,405$1,077Aug 31, 2026Final
Citation 1, item 4b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Aug 31, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(d)

(d) Guarding. All portable, power-driven circular saws shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc required to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc required to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to the covering position.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.