OSHA SearchOSHA records by employer

Tompkins Co Public Safety Building: OSHA inspections and violations

Ithaca, New York · Other General Government Support · NAICS 921190

2inspections
3citation items
$0current penalties
Jun 28, 2016last inspection

OSHA has inspected Tompkins Co Public Safety Building 2 times in New York since 2016.

The latest one began on Jun 28, 2016 to follow up on an earlier case, in Ithaca.

Those inspections ended with 3 citation items: 3 serious.

None of the citations carried a penalty.

How that compares: the median penalty per cited inspection for public administration employers since 2015 is $0, and Tompkins Co Public Safety Building averages $0 (1 cited inspection).

Tompkins Co Public Safety Building: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Tompkins Co Public Safety Building and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341753325 OPENED JUN 28, 2016Closed

Follow-up · Partial · Safety · Local government · 44 employees at the site · Closed Jun 28, 2016

779 Warren Rd, Ithaca, NY 14850 · Other General Government Support · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341251056 OPENED JAN 21, 2016Closed

Complaint · Partial · Safety · Local government · 44 employees at the site · Closed Jun 28, 2016

779 Warren Rd, Ithaca, NY 14850 · Other General Government Support · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Serious$0$0Jun 8, 2016Final
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Jun 8, 2016Final
Citation 1, item 3
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$0$0Jun 8, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.151(c)

(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)(ii)

(ii) Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded.