OSHA SearchOSHA records by employer

Top Notch Home Remodeling LLC: OSHA inspections and violations

Washington, District of Columbia · Framing Contractors · NAICS 238130

2inspections
7citation items
$8,000current penalties
Dec 17, 2024last inspection

Since 2023, OSHA inspectors have visited Top Notch Home Remodeling LLC in District of Columbia 2 times.

The most recent inspection opened on Dec 17, 2024 on a referral, in Washington.

In all, OSHA issued 7 citation items: 1 serious and 6 other-than-serious.

The proposed penalties came to $10,188; today they stand at $8,000, 21% less.

The rule cited most here is 1926.1053 (ladders in construction), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Top Notch Home Remodeling LLC averages $8,000 across 1 cited inspection.

Top Notch Home Remodeling LLC: OSHA citation items per year, 2023 to 2024
Citation items per year, by inspection date.

District of Columbia · latest 90 days of OSHA records

13employers cited

Get notified the morning OSHA posts each new citation in District of Columbia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in District of Columbia

Checking a subcontractor, a client or your own company? Watch Top Notch Home Remodeling LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347938367 OPENED DEC 17, 2024Closed

Referral · Complete · Safety · 5 employees at the site · Closed Jul 23, 2026

2504 41st Nw, Washington, DC 20007 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Other-than-serious$2,170$1,500Mar 4, 2025Final
Citation 1, item 1b
29 CFR 1926.405(b)(2) · Job-site wiring
Other-than-serious$0$0Mar 4, 2025Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,220$4,000Mar 4, 2025Final
Citation 1, item 3a
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$3,798$2,500Mar 4, 2025Final
Citation 1, item 3b
29 CFR 1926.1053(b)(8) · Ladders in construction
Other-than-serious$0$0Mar 4, 2025Final
Citation 1, item 3c
29 CFR 1926.1053(b)(15) · Ladders in construction
Other-than-serious$0$0Mar 4, 2025Final
Citation 1, item 3d
29 CFR 1926.1053(b)(16) · Ladders in construction
Other-than-serious$0$0Mar 4, 2025Final

Inspection 346574254 OPENED MAR 16, 2023Closed

Planned · Complete · Safety · 10 employees at the site · Closed Sep 6, 2023

1000-1099 Webster Street Nw, Washington, DC 20011 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(15)

(15) Ladders shall be inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in District of Columbia

Alert subscribers get notified of each newly cited employer in District of Columbia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.