OSHA SearchOSHA records by employer

Top Plus Construction: OSHA inspections and violations

Peekskill, New York · Framing Contractors · NAICS 238130

2inspections
3citation items
$11,777current penalties
May 14, 2018last inspection

Top Plus Construction has 2 OSHA inspections on record in New York, the first in 2017.

OSHA's last visit started on May 14, 2018, in Brooklyn.

Across those inspections OSHA issued 3 citation items: 3 serious.

OSHA proposed $11,777 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Top Plus Construction averages $5,888 over 2 cited inspections in that time.

Top Plus Construction: OSHA citation items per year, 2017 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites Top Plus Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343192852 OPENED MAY 14, 2018Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed May 7, 2026

140 Martense Street, Brooklyn, NY 11226 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(h)(1) · Woodworking tools
Serious$4,268$4,268Nov 7, 2018Final
Citation 1, item 2
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$2,439$2,439Nov 7, 2018Final

Inspection 342575693 OPENED AUG 23, 2017Closed

Unprogrammed other · Partial · Safety · 11 employees at the site · Closed Jan 14, 2026

1 St. Marys Convent, Peekskill, NY 10566 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$5,070$5,070Sep 28, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(h)(1)

(h) Hand-fed crosscut table saws. (1) Each circular crosscut table saw shall be guarded by a hood which shall meet all the requirements of paragraph (i)(1) of this section for hoods for circular ripsaws.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iii)

(iii) Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other framing contractors employers in New York

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.