Inspection 347843542 OPENED OCT 8, 2024Closed
Community House 46 Church Street, Branford, CT 06405 · Sports and Recreation Instruction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Branford, Connecticut · Highway, Street, and Bridge Construction · NAICS 237310
Since 2015, OSHA inspectors have visited Town of Branford in Connecticut 25 times.
The most recent inspection opened on Oct 8, 2024 as a planned inspection, in Branford.
In all, OSHA issued 94 citation items: 75 serious and 19 other-than-serious.
The proposed penalties came to $17,220; today they stand at $9,570, 44% less.
The rule cited most here is 1910.157 (portable fire extinguishers), 14 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Town of Branford averages $456 across 21 cited inspections.
Town of Branford also files yearly injury logs with OSHA, summarized below.
Connecticut · latest 90 days of OSHA records
83employers cited
5 of them in the same industry
Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Connecticut
Checking a subcontractor, a client or your own company? Watch Town of Branford and get notified the morning OSHA posts a new citation for it.
Watch this companyCommunity House 46 Church Street, Branford, CT 06405 · Sports and Recreation Instruction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
(parks) Hammer Garage 19 Prospect Street, Branford, CT 06405 · General Automotive Repair · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(1) · Walking-working surfaces |
Serious | $400 | $200 | Dec 2, 2024 | Final |
| Citation 1, item 2 29 CFR 1910.37(b)(2) · Exit routes |
Serious | $320 | $160 | Dec 2, 2024 | Final |
| Citation 1, item 3a 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Serious | $320 | $160 | Dec 2, 2024 | Final |
| Citation 1, item 3b 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 4a 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $400 | $200 | Dec 2, 2024 | Final |
| Citation 1, item 4b 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 5a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $320 | $160 | Dec 2, 2024 | Final |
| Citation 1, item 5b 29 CFR 1910.1200(f)(6) · Hazard communication |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 5c 29 CFR 1910.1200(g)(8) · Hazard communication |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 5d 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Dec 2, 2024 | Final |
(parks) Foote Park 12 Melrose Ave, Branford, CT 06405 · Landscaping Services · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Serious | $320 | $160 | Dec 2, 2024 | Final |
| Citation 1, item 1b 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 2a 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $400 | $200 | Dec 2, 2024 | Final |
| Citation 1, item 2b 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Dec 2, 2024 | Final |
Town Hall 1019 Main Street, Branford, CT 06405 · Executive Offices · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(a)(4) · Exit routes |
Serious | $320 | $160 | Dec 2, 2024 | Final |
Fire Headquarters 45 N. Main Street, Branford, CT 06405 · Fire Protection · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.37(b)(2) · Exit routes |
Serious | $240 | $120 | Dec 2, 2024 | Final |
| Citation 1, item 1b 29 CFR 1910.37(b)(6) · Exit routes |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 2a 29 CFR 1910.212(b) · Machine guarding |
Serious | $400 | $200 | Dec 2, 2024 | Final |
| Citation 1, item 2b 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 3a 29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment |
Serious | $400 | $200 | Dec 2, 2024 | Final |
| Citation 1, item 3b 29 CFR 1910.244(a)(2)(vi)(a) · Other portable tools and equipment |
Serious | $0 | $0 | Dec 2, 2024 | Final |
Mp Rice Hose Company 2 341 Main Street, Branford, CT 06405 · Fire Protection · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Dec 2, 2024 | Final |
Indian Neck/pine Orchard Co. 9 6 Linden Ave., Branford, CT 06405 · Fire Protection · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(a)(4) · Exit routes |
Serious | $320 | $160 | Dec 2, 2024 | Final |
Department Of Public Works 137 North Branford Road, Branford, CT 06405 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $480 | $240 | Dec 2, 2024 | Final |
| Citation 1, item 1b 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 1c 29 CFR 1910.134(f)(1) · Respiratory protection |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 2a 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $400 | $200 | Dec 2, 2024 | Final |
| Citation 1, item 2b 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 2c 29 CFR 1910.147(c)(7)(i) · Lockout/tagout |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 3a 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Serious | $320 | $160 | Dec 2, 2024 | Final |
| Citation 1, item 3b 29 CFR 1910.157(g)(2) · Portable fire extinguishers |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 4a 29 CFR 1910.213(c)(1) · Woodworking machinery |
Serious | $560 | $280 | Dec 2, 2024 | Final |
| Citation 1, item 4b 29 CFR 1910.213(c)(2) · Woodworking machinery |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 4c 29 CFR 1910.213(c)(3) · Woodworking machinery |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 5a 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $560 | $280 | Dec 2, 2024 | Final |
| Citation 1, item 5b 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 6 29 CFR 1910.244(a)(2)(vi)(a) · Other portable tools and equipment |
Serious | $240 | $120 | Dec 2, 2024 | Final |
| Citation 1, item 7a 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $400 | $200 | Dec 2, 2024 | Final |
| Citation 1, item 7b 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 7c 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $0 | $0 | Dec 2, 2024 | Final |
Transfer Station 747 E. Main Street, Branford, CT 06405 · Solid Waste Collection · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Serious | $240 | $120 | Dec 2, 2024 | Final |
| Citation 1, item 1b 29 CFR 1910.157(g)(2) · Portable fire extinguishers |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 2 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $320 | $160 | Dec 2, 2024 | Final |
Police Department 33 Laurel Street, Branford, CT 06405 · Police Protection · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $320 | $160 | Dec 2, 2024 | Final |
| Citation 1, item 1b 29 CFR 1910.1200(g)(8) · Hazard communication |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 1c 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 2, item 1 29 CFR 1910.120(q)(8)(i) · Hazardous waste operations and emergency response |
Other-than-serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 2, item 2 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Dec 2, 2024 | Final |
Robert Cosgrove Animal Shelter 749 E. Main Street, Branford, CT 06405 · Pet Care (except Veterinary) Services · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Serious | $240 | $120 | Dec 2, 2024 | Final |
| Citation 1, item 1b 29 CFR 1910.157(g)(2) · Portable fire extinguishers |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 2a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $400 | $200 | Dec 2, 2024 | Final |
| Citation 1, item 2b 29 CFR 1910.1200(e)(1)(i) · Hazard communication |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 2c 29 CFR 1910.1200(g)(8) · Hazard communication |
Serious | $0 | $0 | Dec 2, 2024 | Final |
| Citation 1, item 2d 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Dec 2, 2024 | Final |
Branford Dpw 137 N. Branford Rd., Branford, CT 06405 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Dpw Maintenance Garage 137 North Branford Road, Branford, CT 06405 · General Automotive Repair · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Town Hall 1019 Main Street, Branford, CT 06405 · Executive Offices · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.1200(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
Department Of Public Works, Maintenance Garage 137 North Branford Road, Branford, CT 06405 · General Automotive Repair · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.101(b) · Compressed gases (general requirements) |
Serious | $420 | $210 | Sep 16, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes |
Serious | $420 | $210 | Sep 16, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.184(e)(1) · Slings |
Serious | $420 | $210 | Sep 16, 2016 | Final |
| Citation 1, item 4 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $280 | $140 | Sep 16, 2016 | Final |
| Citation 1, item 5 29 CFR 1910.213(b)(3) · Woodworking machinery |
Serious | $350 | $175 | Sep 16, 2016 | Final |
| Citation 1, item 6 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $350 | $175 | Sep 16, 2016 | Final |
| Citation 1, item 7a 29 CFR 1910.254(b)(4)(iv) · Arc welding and cutting |
Serious | $420 | $210 | Sep 16, 2016 | Final |
| Citation 1, item 7b 29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting |
Serious | $0 | $0 | Sep 16, 2016 | Final |
| Citation 1, item 9a 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Serious | $210 | $105 | Sep 16, 2016 | Final |
| Citation 1, item 9b 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Sep 16, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.95(d)(1) · Noise |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.244(a)(2)(vi)(a) · Other portable tools and equipment |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
| Citation 2, item 3 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
Department Of Public Works Mill Plain Road (road Job), Branford, CT 06405 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 31-370(A) |
Serious | $490 | $245 | Sep 16, 2016 | Final |
| Citation 1, item 2 29 CFR 1926.200(g)(2) · Accident prevention signs and tags |
Serious | $640 | $320 | Sep 16, 2016 | Final |
Department Of Solid Waste, Transfer Station 747 East Main Street, Branford, CT 06405 · Materials Recovery Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Water Pollution Control Facility 75 Block Island Road, Branford, CT 06405 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.146(c)(2) · Permit-required confined spaces |
Serious | $490 | $245 | Sep 16, 2016 | Final |
| Citation 1, item 1b 29 CFR 1910.146(c)(4) · Permit-required confined spaces |
Serious | $0 | $0 | Sep 16, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $420 | $210 | Sep 16, 2016 | Final |
| Citation 1, item 3a 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $280 | $140 | Sep 16, 2016 | Final |
| Citation 1, item 3b 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Sep 16, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.95(d)(1) · Noise |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.1200(f)(6)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
Wpcf Pump Station Route 139 North Branford Road, Branford, CT 06405 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $490 | $245 | Sep 16, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
Wpcf Pump Station 141 Chestnut Hill Road, Branford, CT 06405 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.146(c)(2) · Permit-required confined spaces |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
Wpcf Pump Station 171 Cedar Street, Branford, CT 06405 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.146(c)(2) · Permit-required confined spaces |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
Parks And Recreation Department 46 Church Street, Branford, CT 06405 · All Other Amusement and Recreation Industries · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.1030(c)(1)(i) · Bloodborne pathogens |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
Parks & Recreation Department, Hammer Field Maintenance Garage 17 Prospect Street, Branford, CT 06405 · General Automotive Repair · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.101(b) · Compressed gases (general requirements) |
Serious | $280 | $140 | Sep 16, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $280 | $140 | Sep 16, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.95(d)(1) · Noise |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.244(a)(2)(vi)(a) · Other portable tools and equipment |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
Department Of General Government Buildings Storage Area 137 North Branford Road, Branford, CT 06405 · Other General Government Support · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $420 | $210 | Sep 16, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.22(a)(1) · General requirements |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.1200(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
Department Of Public Works 137 North Branford Road, Branford, CT 06405 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Serious | $640 | $640 | Jul 22, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $640 | $640 | Jul 22, 2015 | Final |
| Citation 1, item 3 29 CFR 1910.304(b)(3) · Grounding and circuit protection |
Serious | $640 | $640 | Jul 22, 2015 | Final |
| Citation 2, item 1 29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jul 22, 2015 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Branford site logged 5 recordable injuries or illnesses among about 76 workers: 6.3 per 100 full-time workers, against a median of 3.1 for its industry. Those cases cost 88 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Police Department Branford · 2024 | 76 | 5 | 4 | 6.3 | 3.1 |
| Public Works Branford · 2024 | 22 | 2 | 2 | 11.6 | 3.1 |
| Animal Shelter Branford · 2023 | 11 | 1 | 0 | 13.6 | 3.1 |
| Fire Department Branford · 2020 | 80 | 9 | 2 | 21.8 | 5.5 |
| Town Hall Branford · 2020 | 38 | 1 | 1 | 2.8 | 3.1 |
| Community Center Branford · 2020 | 47 | 1 | 1 | 4.6 | 2.2 |
| Branford Counseling and Community Services Branford · 2020 | 22 | 0 | 0 | 0.0 | 2.6 |
| Waste Water Treatment Facility Branford · 2020 | 16 | 1 | 0 | 7.2 | 3.0 |
Included with any plan: 57 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.101(b)
(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.
29 CFR 1910.1030(c)(1)(i)
(c) Exposure control—(1) Exposure Control Plan. (i) Each employer having an employee(s) with occupational exposure as defined by paragraph (b) of this section shall establish a written Exposure Control Plan designed to eliminate or minimize employee exposure.
29 CFR 1910.120(q)(8)(i)
(8) Refresher training. (i) Those employees who are trained in accordance with paragraph (q)(6) of this section shall receive annual refresher training of sufficient content and duration to maintain their competencies, or shall demonstrate competency in those areas at least yearly.
Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.