Inspection 342053899 OPENED JAN 17, 2017Closed
1 Bond Drive, Union, NJ 07083 · Ambulance Services · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Union, New Jersey · Sewage Treatment Facilities · NAICS 221320
OSHA has inspected Township of Union 9 times in New Jersey since 2003.
The latest one began on Jan 17, 2017 as part of a related case, in Union.
Those inspections ended with 23 citation items: 17 serious and 6 other-than-serious.
Penalties were first proposed at $53,200 and still stand at $53,200.
Electrical equipment, general requirements comes up most often in these citations: 6 items under 1910.303.
How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Township of Union averages $26,600 (2 cited inspections).
New Jersey · latest 90 days of OSHA records
270employers cited
7 of them in the same industry
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New Jersey
Checking a subcontractor, a client or your own company? Watch Township of Union and get notified the morning OSHA posts a new citation for it.
Watch this company1 Bond Drive, Union, NJ 07083 · Ambulance Services · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1 Swanstrom Place, Union, NJ 07083 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1 Swanstrom Place, Union, NJ 07083 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1 Swanstrom Place, Union, NJ 07083 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.106(d)(2)(i) · Flammable liquids |
Serious | $4,900 | $4,900 | Sep 28, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.176(c) · Material storage and aisles |
Serious | $4,900 | $4,900 | Sep 28, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $4,900 | $4,900 | Sep 28, 2016 | Final |
| Citation 1, item 4 29 CFR 1910.305(a)(2)(i) · Electrical wiring methods |
Serious | $4,900 | $4,900 | Sep 28, 2016 | Final |
| Citation 1, item 5 29 CFR N.J.S.A. 34:6A-33(A) |
Serious | $4,900 | $4,900 | Sep 28, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $700 | $700 | Sep 28, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.146(c)(3) · Permit-required confined spaces |
Other-than-serious | $700 | $700 | Sep 28, 2016 | Final |
| Citation 2, item 3 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Other-than-serious | $700 | $700 | Sep 28, 2016 | Final |
1 Swanstrom Place, Union, NJ 07083 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.146(c)(5)(ii)(b) · Permit-required confined spaces |
Serious | $4,900 | $4,900 | Oct 6, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Serious | $4,900 | $4,900 | Oct 6, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements |
Serious | $4,900 | $4,900 | Oct 6, 2016 | Final |
| Citation 1, item 4 29 CFR 1910.303(h)(2)(iii)(b) · Electrical equipment, general requirements |
Serious | $4,900 | $4,900 | Oct 6, 2016 | Final |
| Citation 1, item 5 29 CFR 1910.305(j)(2)(vii) · Electrical wiring methods |
Serious | $4,900 | $4,900 | Oct 6, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.146(c)(3) · Permit-required confined spaces |
Other-than-serious | $700 | $700 | Oct 6, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.147(c)(4)(ii)(b) · Lockout/tagout |
Other-than-serious | $700 | $700 | Oct 6, 2016 | Final |
| Citation 2, item 3 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Other-than-serious | $700 | $700 | Oct 6, 2016 | Final |
Road Department, Hampton, NJ 08827 · Facilities Support Services · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Road Department, Hampton, NJ 08827 · Facilities Support Services · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1s 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $0 | $0 | Nov 17, 2005 | Closed |
| Citation 1, item 2s 29 CFR 1910.157(g)(2) · Portable fire extinguishers |
Serious | $0 | $0 | Nov 17, 2005 | Closed |
| Citation 1, item 3s 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Nov 17, 2005 | Closed |
| Citation 1, item 4s 29 CFR 1910.304(f)(1)(iv) · Grounding and circuit protection |
Serious | $0 | $0 | Nov 17, 2005 | Closed |
| Citation 1, item 5s 29 CFR 70005 A |
Serious | $0 | $0 | Nov 17, 2005 | Closed |
Union Fire Dept., Union, NJ 07083 · Fire Protection · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Union Fire Dept., Union, NJ 07083 · Fire Protection · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1s 29 CFR 100006 A01 |
Serious | $0 | $0 | Jun 12, 2003 | Closed |
| Citation 1, item 2s 29 CFR 100009 A |
Serious | $0 | $0 | Jun 12, 2003 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(2)(i)
(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.
29 CFR 1910.132(d)(2)
(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.
29 CFR 1910.146(c)(3)
(3) If the employer decides that its employees will not enter permit spaces, the employer shall take effective measures to prevent its employees from entering the permit spaces and shall comply with paragraphs (c)(1), (c)(2), (c)(6), and (c)(8) of this section.
Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.