Inspection 349179556 OPENED SEP 22, 2026Closed
82 Clarendon Road, Asheville, NC 28806 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Asheville, North Carolina · Water and Sewer Line and Related Structures Construction · NAICS 237110
TP Howard's Plumbing Company has 3 OSHA inspections on record in North Carolina, the first in 2024.
OSHA's last visit started on Sep 22, 2026 after a complaint, in Asheville.
Across those inspections OSHA issued 3 citation items: 3 serious.
OSHA proposed $44,685 in penalties. After settlements and reviews the total is $28,995, down 35%.
Most often, OSHA cited 1926.651, excavations (2 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. TP Howard's Plumbing Company averages $28,995 over 1 cited inspection in that time.
North Carolina · latest 90 days of OSHA records
228employers cited
4 of them in the same industry
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch TP Howard's Plumbing Company and get notified the morning OSHA posts a new citation for it.
Watch this company82 Clarendon Road, Asheville, NC 28806 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
146 Smokey Park Highway, Asheville, NC 28806 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(c)(2) · Excavations |
Serious | $14,895 | $9,665 | Oct 16, 2025 | Final |
| Citation 1, item 2 29 CFR 1926.651(j)(2) · Excavations |
Serious | $14,895 | $9,665 | Oct 16, 2025 | Final |
| Citation 1, item 3 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $14,895 | $9,665 | Oct 16, 2025 | Final |
1085 Hendersonville Road, Biltmore Forest, NC 28803 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.651(c)(2)
(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.
29 CFR 1926.651(j)(2)
(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.
29 CFR 1926.652(a)(1)
(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.