OSHA SearchOSHA records by employer

Trane U.S. Inc.: OSHA inspections and violations

Tyler, Texas · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · NAICS 333415

5inspections
3citation items
$88,506current penalties
Jul 19, 2022last inspection

Trane U.S. Inc. has 5 OSHA inspections on record in Texas, the first in 2018.

OSHA's last visit started on Jul 19, 2022 after a complaint, in Tyler.

Across those inspections OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $91,462 in penalties. After settlements and reviews the total is $88,506, down 3%.

Most often, OSHA cited 1910.212, machine guarding (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Trane U.S. Inc. averages $44,253 over 2 cited inspections in that time.

Trane U.S. Inc. also files yearly injury logs with OSHA, summarized below.

It reported 4 severe injuries to OSHA since 2015.

Trane U.S. Inc.: OSHA citation items per year, 2018 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Trane U.S. Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346087588 OPENED JUL 19, 2022Closed

Complaint · Complete · Health · 2,400 employees at the site · Closed Aug 22, 2022

6200 Troup Hwy, Tyler, TX 75707 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344011549 OPENED MAY 14, 2019Closed

Follow-up · Partial · Safety · 2,180 employees at the site · Closed Jun 13, 2019

6200 Troup Highway, Tyler, TX 75707 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344025382 OPENED MAY 14, 2019Closed

Follow-up · Partial · Safety · 2,180 employees at the site · Closed Jun 13, 2019

6200 Troup Highway, Tyler, TX 75707 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343213088 OPENED JUN 7, 2018Closed

Referral · Partial · Safety · 1,600 employees at the site · Closed Oct 19, 2018

6200 Troup Hwy., Tyler, TX 75707 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jun 4, 2018: Employee sustains amputation of fingertip and thumb

At 10:45 a.m. on June 4, 2018, an employee was working for a manufacturer of air conditioning and heating equipment and commercial and industrial refrigeration equipment. He was troubleshooting the facility's tube fabrication saw machine Number 170. The tip of the index finger and the thumb on his right hand became caught in a tooling clamp on the machine. The clamp on the machine pulled the fingertip and the thumb into the tooling. The employee sustained the amputation of his fingertip and thumb.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$12,934$12,934Aug 15, 2018Final
Citation 2, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$71,137$71,137Aug 15, 2018Final

Inspection 343035580 OPENED MAR 22, 2018Closed

Referral · Partial · Safety · 2,000 employees at the site · Closed Jun 14, 2018

6200 Troup Hwy, Tyler, TX 75707 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Mar 15, 2018: Employee fractures toe when caught in elevator

At 5:30 p.m. on March 15, 2018, Employee #1 went to the front of the elevator and starting to secure the wires and sensors on the air conditioning units being assembled on an assembly line, after the sheet metal body had been added. As the employee worked on the unit, it twisted as it entered the elevator and jammed. The employee placed her right foot on top of the cross bar frame and was standing with her heel against the exterior cross bar framework of the elevator housing. The employee used her hands to push on the corner of the unit. This caused the unit to turn back to its proper position. The assembly line was still on, so when the unit straightened out, it went into the elevator and actuated a pressure switch. This activated the pneumatically controlled elevator, causing it to drop approximately eight inches. When the cross bar frame of the elevator, which houses the elevator, came down, it trapped the employees right foot between the two cross pieces, fracturing her right little toe. Employee #1 was hospitalized for treatment.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$7,391$4,435May 4, 2018Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2019, the Tyler site logged 36 recordable injuries or illnesses among about 1,863 workers: 1.9 per 100 full-time workers, against a median of 2.4 for its industry. Those cases cost 161 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Residential HVAC and Supply : MFG-Tyler,TX-USA
Tyler · 2019
1,863 3641.92.4

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 4 reports on file.

May 11, 2021, Tyler: Amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee was rolling an 800-pound reel of aluminum into the storage area when his left index finger was caught and amputated between two reels.

Nov 13, 2018, Tyler: Hospitalization · fractures · chest, except internal location of diseases or disorders

An employee ran into a flatbed trailer while driving a golf cart, suffering rib fractures that required hospitalization.

Jun 4, 2018, Tyler: Amputation · amputations · fingertip(s)

An employee was troubleshooting a machine when his right index finger and thumb were caught in the tooling clamp, amputating the tips. An energy isolating device was not used during this process.

Mar 15, 2018, Tyler: Hospitalization · soreness, pain, hurt-nonspecified injury · toes(s), toenail(s)

An employee was attempting to push an AC unit that was stuck on a conveyor elevator down with her foot when one of her right toes was caught between the elevator and the framework as the elevator was descending.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(ii)

(ii) The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

Other air-conditioning and warm air heating equipment and commercial and industrial refrigeration equipment manufacturing employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.