Transformer Maintenance and Service, Inc.: OSHA inspections and violations

Maxton, North Carolina · Power, Distribution, and Specialty Transformer Manufacturing · NAICS 335311

1inspections
3citation items
$11,200current penalties
Nov 23, 2015last inspection

Transformer Maintenance and Service, Inc. has one OSHA inspection on record in North Carolina.

OSHA opened it on Nov 23, 2015 on a referral, in Maxton.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $11,200 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.269, electric power generation, transmission, and distribution (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Transformer Maintenance and Service, Inc. averages $11,200 over 1 cited inspection in that time.

Transformer Maintenance and Service, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Transformer Maintenance and Service, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341076453 OPENED NOV 23, 2015Closed

Referral · Partial · Safety · 80 employees at the site · Closed Feb 25, 2016

227 Charles Watts Rd., Maxton, NC 28364 · Power, Distribution, and Specialty Transformer Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.269(a)(3)(iii) · Electric power generation, transmission, and distribution
Serious$3,500$3,500Jan 7, 2016Final
Citation 1, item 2
29 CFR 1910.269(c)(2) · Electric power generation, transmission, and distribution
Serious$3,500$3,500Jan 7, 2016Final
Citation 1, item 3
29 CFR 1910.269(m)(3)(vi) · Electric power generation, transmission, and distribution
Serious$4,200$4,200Jan 7, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.269 · Electric power generation, transmission, and distribution

29 CFR 1910.269(a)(3)(iii)

(iii) The contract employer and the host employer shall coordinate their work rules and procedures so that each employee of the contract employer and the host employer is protected as required by this section.

29 CFR 1910.269(c)(2)

(2) Subjects to be covered. The briefing shall cover at least the following subjects: hazards associated with the job, work procedures involved, special precautions, energy-source controls, and personal protective equipment requirements.

29 CFR 1910.269(m)(3)(vi)

(vi) After the applicable requirements in paragraphs (m)(3)(i) through (m)(3)(v) of this section have been followed and the system operator gives a clearance to the employee in charge, the employer shall ensure that the lines and equipment are deenergized by testing the lines and equipment to be worked with a device designed to detect voltage.

Other power, distribution, and specialty transformer manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.