Inspection 346919830 OPENED AUG 18, 2023Closed
205 Shellhouse Drive, Rantoul, IL 61866 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Transom Symphony Opco, LLC dba Beauty Quest Group 3 times in Illinois since 2022.
The latest one began on Aug 18, 2023 on a referral, in Rantoul.
Those inspections ended with 8 citation items: 8 serious.
Penalties were first proposed at $95,768 and now stand at $55,987, 42% lower after settlements or reviews.
Lockout/tagout comes up most often in these citations: 7 items under 1910.147.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Transom Symphony Opco, LLC dba Beauty Quest Group averages $27,994 (2 cited inspections).
It reported 2 severe injuries to OSHA since 2015.
Illinois · latest 90 days of OSHA records
416employers cited
Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Illinois
Checking a subcontractor, a client or your own company? Watch Transom Symphony Opco, LLC dba Beauty Quest Group and get notified the morning OSHA posts a new citation for it.
Watch this company205 Shellhouse Drive, Rantoul, IL 61866 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
205 Shellhouse Drive, Rantoul, IL 61866 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $12,278 | $12,278 | Sep 8, 2023 | Final |
| Citation 1, item 1b 29 CFR 1910.147(d) · Lockout/tagout |
Serious | $12,278 | $0 | Sep 8, 2023 | Final |
| Citation 1, item 3 29 CFR 1910.303(g)(1) · Electrical equipment, general requirements |
Serious | $9,822 | $6,875 | Sep 8, 2023 | Final |
205 Shellhouse Drive, Rantoul, IL 61866 · Toilet Preparation Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(ii)(a) · Lockout/tagout |
Serious | $12,278 | $7,367 | Mar 13, 2023 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(4)(ii)(d) · Lockout/tagout |
Serious | $12,278 | $7,367 | Mar 13, 2023 | Final |
| Citation 1, item 3 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $12,278 | $7,367 | Mar 13, 2023 | Final |
| Citation 1, item 4 29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout |
Serious | $12,278 | $7,367 | Mar 13, 2023 | Final |
| Citation 1, item 5 29 CFR 1910.147(d) · Lockout/tagout |
Serious | $12,278 | $7,367 | Mar 13, 2023 | Final |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.
May 11, 2023, Rantoul: Amputation · amputations · finger(s), fingernail(s), unspecified
On May 11, 2023, an employee was adjusting the torque settings on a capper on a line. The employee dropped a tool and as they went to reach for it, their finger struck the top belt drive in the machine. The employee's right ring finger was partially amputated.
Nov 22, 2022, Rantoul: Amputation · amputations · finger(s), fingernail(s), unspecified
On November 22, 2022, at approximately 8:00 AM, an employee was performing maintenance activities on an aerosol production line valve when their finger was caught in the moving machinery. The employee sustained a finger amputation.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.147(c)(4)(i)
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(4)(ii)(a)
(A) A specific statement of the intended use of the procedure;
29 CFR 1910.147(c)(4)(ii)(d)
(D) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.