OSHA SearchOSHA records by employer

Travers Electric, Inc.: OSHA inspections and violations

Waterville, Maine · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

8inspections
9citation items
$8,084current penalties
Jun 2, 2017last inspection

OSHA has inspected Travers Electric, Inc. 8 times in Maine since 1974.

The latest one began on Jun 2, 2017 on a referral, in Skowhegan.

Those inspections ended with 9 citation items: 6 serious and 3 other-than-serious.

Penalties were first proposed at $13,067 and now stand at $8,084, 38% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 2 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Travers Electric, Inc. averages $6,084 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Travers Electric, Inc.: OSHA citation items per year, 1974 to 2017
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch Travers Electric, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342371168 OPENED JUN 2, 2017Closed

Referral · Partial · Safety · 12 employees at the site · Closed Jul 11, 2017

6 Commerce Drive, Skowhegan, ME 04976 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on May 25, 2017: Employee sustains broken pelvis when scissor lift tips over

At 9:00 a.m. on May 25, 2017, Employee #1 was using a scissor lift to raise a light pole to fasten it in position. At an unknown height, the lift tipped over and Employee #1 sustained a broken pelvis. As a result, he was hospitalized and treated. The incident investigation determined that a combination of the weight of the pole with the slope of the ground caused the incident. incident.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.452(w)(1) · Rules for each type of scaffold
Serious$5,070$3,549Jun 20, 2017Final
Citation 1, item 2
29 CFR 1926.454(a) · Scaffold training
Serious$3,622$2,535Jun 20, 2017Final

Inspection 334476934 OPENED MAY 24, 2012Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Jun 15, 2012

93 Main Street, Waterville, ME 04901 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$2,800$1,400Jun 1, 2012Final

Inspection 112516869 OPENED AUG 9, 2005Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Sep 19, 2005

Bangor International Airport, Bangor, ME 04401 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$375$375Aug 24, 2005Closed

Inspection 305587420 OPENED JUL 25, 2002Closed

Unprogrammed other · Complete · Safety · 8 employees at the site · Closed Sep 25, 2002

Middle Street, Farmington, ME 04938 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(iie) · Job-site wiring
Serious$225$112Sep 19, 2002Closed
Citation 1, item 2
29 CFR 1926.21(b)(2) · Construction safety training
Serious$225$112Sep 19, 2002Closed

Inspection 301663191 OPENED JUL 9, 1998Closed

Unprogrammed other · Complete · Safety · 1 employee at the site · Closed Jul 17, 1998

Poland Middle/high School, Poland, ME 04273 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109797548 OPENED APR 20, 1994Closed

Complaint · Complete · Safety · 8 employees at the site · Closed Jul 12, 1994

Blaine Avenue, Guilford Middle School, Guilford, ME 04443 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.417(d)(1) · Lockout and tagging of circuits
Other-than-serious$750$0May 19, 1994Closed

Inspection 18060533 OPENED AUG 8, 1990Closed

Unprogrammed related · Complete · Safety · 2 employees at the site · Closed Dec 17, 1990

Farmington Elementary School, Farmington, ME 04938 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0Aug 17, 1990Closed
Citation 1, item 2
29 CFR 1926.405(a)(2)(iie) · Job-site wiring
Other-than-serious$0$0Aug 17, 1990Closed

Inspection 10407377 OPENED SEP 17, 1974Closed

Planned · Complete · Safety · 1 employee at the site · Closed Mar 10, 1984

Office & Gapage Building, Waterville, ME 04901 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

May 25, 2017, Skowhegan: Hospitalization · fractures · pelvis

An employee was performing electrical work from the platform of a scissor lift when the scissor lift tipped over. The employee fell 20 to 25 feet to the ground and suffered a fractured pelvis.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.417 · Lockout and tagging of circuits

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other electrical contractors and other wiring installation contractors employers in Maine

Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.