OSHA SearchOSHA records by employer

Tri Star Construction: OSHA inspections and violations

New York, New York · Commercial and Institutional Building Construction · NAICS 236220

6inspections
8citation items
$14,750current penalties
Oct 12, 2023last inspection

OSHA has inspected Tri Star Construction 6 times in New York since 2000.

The latest one began on Oct 12, 2023 on a referral, in Staten Island.

Those inspections ended with 8 citation items: 8 serious.

Penalties were first proposed at $26,050 and now stand at $14,750, 43% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 3 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Tri Star Construction averages $5,000 (1 cited inspection).

Tri Star Construction: OSHA citation items per year, 2000 to 2023
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Tri Star Construction and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347054058 OPENED OCT 12, 2023Closed

Referral · Partial · Safety · 9 employees at the site · Closed Feb 9, 2024

60 Decker Ave., Staten Island, NY 10302 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$6,250$2,500Nov 22, 2023Final
Citation 1, item 2
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$6,250$2,500Nov 22, 2023Final

Inspection 346128366 OPENED JUL 30, 2022Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Jan 26, 2023

85 10th Avenue, New York, NY 10011 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341260982 OPENED FEB 17, 2016Closed

Complaint · Partial · Safety · 1 employee at the site · Closed May 31, 2016

350 5th Avenue, New York, NY 10118 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339561870 OPENED JAN 24, 2014Closed

Referral · Complete · Safety · 2 employees at the site · Closed Dec 8, 2014

20 East 64th Street, New York, NY 10065 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3a
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$2,800$1,800Jul 18, 2014Final
Citation 1, item 3b
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$2,800$0Jul 18, 2014Final

Inspection 314462888 OPENED AUG 23, 2010Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jul 25, 2011

1065 6th Avenue, New York, NY 10018 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$1,250$1,250Nov 3, 2010Closed
Citation 1, item 2
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$1,250$1,250Nov 3, 2010Closed
Citation 1, item 3
29 CFR 1926.405(j)(1)(ii) · Job-site wiring
Serious$1,250$1,250Nov 3, 2010Closed

Inspection 302943147 OPENED OCT 27, 2000Closed

Unprogrammed other · Partial · Safety · 50 employees at the site · Closed Dec 5, 2000

123 Perry Street,, New York, NY 10014 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$4,200$4,200Nov 13, 2000Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.501 · Fall protection in construction

Other commercial and institutional building construction employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.