OSHA SearchOSHA records by employer

Tri State Chimney & Masonry Service Inc.: OSHA inspections and violations

Holden, Massachusetts · Other Services to Buildings and Dwellings · NAICS 561790

2inspections
11citation items
$9,388current penalties
Sep 5, 2023last inspection

Since 2023, OSHA inspectors have visited Tri State Chimney & Masonry Service Inc. in Massachusetts 2 times.

The most recent inspection opened on Sep 5, 2023 as part of a related case, in Holden.

In all, OSHA issued 11 citation items: 10 serious and 1 other-than-serious.

The proposed penalties came to $24,110; today they stand at $9,388, 61% less.

The rule cited most here is 1910.134 (respiratory protection), 4 times.

Among staffing, cleaning and waste services employers, the typical cited inspection since 2015 ends with a $2,232 penalty. Tri State Chimney & Masonry Service Inc. averages $4,694 across 2 cited inspections.

Tri State Chimney & Masonry Service Inc.: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

264employers cited

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Tri State Chimney & Masonry Service Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346954399 OPENED SEP 5, 2023Closed

Programmed related · Partial · Health · 3 employees at the site · Closed May 14, 2024

101 Highland Ave, Holden, MA 01520 · Other Services to Buildings and Dwellings · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$4,688$2,350Jan 11, 2024Final
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jan 11, 2024Final
Citation 1, item 1c
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Jan 11, 2024Final
Citation 1, item 1d
29 CFR 1910.134(k) · Respiratory protection
Serious$0$0Jan 11, 2024Final
Citation 1, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$2,679$0Jan 11, 2024Final
Citation 1, item 3a
29 CFR 1926.1153(c)(1) · Silica dust in construction
Serious$4,688$2,350Jan 11, 2024Final
Citation 1, item 3b
29 CFR 1926.1153(d)(2)(i) · Silica dust in construction
Serious$0$0Jan 11, 2024Final
Citation 1, item 4
29 CFR 1926.1153(g)(1) · Silica dust in construction
Serious$2,679$0Jan 11, 2024Final

Inspection 346956154 OPENED SEP 5, 2023Closed

Planned · Partial · Safety · 3 employees at the site · Closed Apr 9, 2024

101 Highland Ave., Holden, MA 01507 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,688$4,688Nov 27, 2023Final
Citation 1, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$4,688$0Nov 27, 2023Final
Citation 1, item 1c
29 CFR 1926.503(b)(1) · Fall protection training in construction
Serious$0$0Nov 27, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1926.1153 · Silica dust in construction

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other other services to buildings and dwellings employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.