Tri-State Electric Ltd: OSHA inspections and violations
El Paso, Texas · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210
15inspections
8citation items
$10,650current penalties
Aug 21, 2025last inspection
Tri-State Electric Ltd has 15 OSHA inspections on record in Texas, the first in 1987.
OSHA's last visit started on Aug 21, 2025 as a planned inspection, in El Paso.
Across those inspections OSHA issued 8 citation items: 3 serious and 5 other-than-serious.
OSHA proposed $17,267 in penalties. After settlements and reviews the total is $10,650, down 38%.
Most often, OSHA cited 1926.404, ground-fault protection on job sites (2 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Tri-State Electric Ltd averages $5,000 over 1 cited inspection in that time.
1 inspection on this page followed a fatal incident.
Tri-State Electric Ltd also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Texas · latest 90 days of OSHA records
398employers cited
7 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
Planned · Partial · Safety · 5 employees at the site · Closed Mar 17, 2026
6927 N. Mesa St. And Champions Ln. By Restler Canyon, El Paso, TX 79912 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
Referral · Partial · Safety · 10 employees at the site · Closed Sep 27, 2018
Vicinity Of I-10 & Mesa Hills I-10 Construction Project, El Paso, TX 79902 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
Incident on May 31, 2018: Employee's finger is smashed by treading tool
At 2:30 p.m. on May 31, 2018, Employee #1, employed by an electrical services company, was using a treading tool to tread a section of steel tubing. During this process, the tool's handle swung downward, striking and smashing the employee's left index finger. The employee was transported to the hospital, admitted, and treated for this finger crushing injury.
No citations from this inspection.
Inspection 342994563 OPENED MAR 6, 2018Closed
Fatality or catastrophe · No inspection · Health · 170 employees at the site · Closed Apr 5, 2018
Hwy Us-54 Median Between Hondo Pass And Transmountain, El Paso, TX 79930 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 340909589 OPENED SEP 10, 2015Closed
Complaint · Partial · Safety · 100 employees at the site · Closed Jan 21, 2016
Incident on May 11, 2009 (fatal): Welder experiences seizure and is found dead at workstation
At approximately 10:00 a.m. on May 11, 2009, a welder, who had worked for Tri-St ate Electric since September 29, 2003, was found dead at his workstation. Accord ing to coworkers, he was known to experience seizures. A bottle of his medicatio n was found to be empty. It was believed that the employee experienced a seizure and died onsite, but the medical examiner's report had yet to be issued.
No citations from this inspection.
Inspection 307243816 OPENED FEB 21, 2005Closed
Unprogrammed other · Partial · Safety · 20 employees at the site · Closed Mar 30, 2005
Planned · Partial · Safety · 75 employees at the site · Closed Apr 20, 2004
Gateway West Approx. 1 Mile West Of Eastlake Dr., El Paso, TX 79927 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 301568788 OPENED AUG 11, 1999Closed
Programmed other · Partial · Safety · 3 employees at the site · Closed Nov 4, 1999
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2019, the Vinton site logged 6 recordable injuries or illnesses among about 171 workers: 3.1 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 145 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Tri-State Electric, Ltd
Vinton · 2019
171
6
2
3.1
1.8
Severe injury reports
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
May 31, 2018, El Paso: Hospitalization, amputation · amputations · finger(s), fingernail(s), unspecified
An employee was using a tread machine when it became stuck, causing the handle on the tread machine to spin and pinch the employee's left index finger between the machine and the bumper of the truck next to him, resulting in an amputation.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(b) The equipment must not be assembled or used unless ground conditions are firm, drained, and graded to a sufficient extent so that, in conjunction (if necessary) with the use of supporting materials, the equipment manufacturer's specifications for adequate support and degree of level of the equipment are met. The requirement for the ground to be drained does not apply to marshes/wetlands.
(ii) In locations where electric equipment would be exposed to physical damage, enclosures or guards shall be so arranged and of such strength as to prevent such damage.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.