OSHA SearchOSHA records by employer

Tri-State Renovating: OSHA inspections and violations

New York, New York · Framing Contractors · NAICS 238130

2inspections
3citation items
$8,316current penalties
Jul 2, 2019last inspection

OSHA has inspected Tri-State Renovating 2 times in New York since 2017.

The latest one began on Jul 2, 2019 to follow up on an earlier case, in New York.

Those inspections ended with 3 citation items: 3 serious.

Penalties were first proposed at $8,316 and still stand at $8,316.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Tri-State Renovating averages $8,316 (1 cited inspection).

Tri-State Renovating: OSHA citation items per year, 2017 to 2019
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

19 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Tri-State Renovating and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344125554 OPENED JUL 2, 2019Closed

Follow-up · Partial · Safety · 2 employees at the site · Closed Aug 1, 2019

63 West 130th Street, New York, NY 10037 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342845633 OPENED DEC 18, 2017Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Jan 19, 2023

63 West 130th Street, New York, NY 10037 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$2,772$2,772Jan 31, 2018Final
Citation 1, item 2
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$2,772$2,772Jan 31, 2018Final
Citation 1, item 3
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$2,772$2,772Jan 31, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

Other framing contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.