OSHA has inspected Trienda Holdings, L.L.C. 4 times in Wisconsin since 2017.
The latest one began on Nov 7, 2024 after a complaint, in Portage.
Those inspections ended with 6 citation items: 6 serious.
Penalties were first proposed at $63,791 and now stand at $44,337, 30% lower after settlements or reviews.
Machine guarding comes up most often in these citations: 2 items under 1910.212.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Trienda Holdings, L.L.C. averages $11,084 (4 cited inspections).
It reported 6 severe injuries to OSHA since 2015.
Inspection 345068779 OPENED DEC 16, 2020Closed
Referral · Partial · Safety · 250 employees at the site · Closed Jan 24, 2022
N 7660 Industrial Road, Portage, WI 53901 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Dec 13, 2020: Employee amputates finger due to contact with moving fan bla
At 10:40 p.m. on December 13, 2020, Employee #1, a Thermoformer machine/line operator, was adjusting a machine-mounted fan that was positioned less than seven feet from the walking surface. During the adjustment, Employee #1's left middle finger came into contact with the moving fan blade, resulting in an amputation of the first digit. Although the mounted fan was equipped with a guard (shroud), the openings in the shroud were large enough for the employee's fingers to pass through and make contact with the moving blades. The employee was hospitalized. The incident occurred indoors, and weather conditions were not a factor.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Serious | $9,753 | $8,290 | Apr 23, 2021 | Final |
Inspection 343125779 OPENED MAY 1, 2018Closed
Referral · Partial · Safety · 270 employees at the site · Closed Jul 10, 2018
N7660 Industrial Road, Portage, WI 53901 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Apr 24, 2018: Employee falls through floor cover and sustains injuries
At 8:00 a.m. on April 24, 2018, an employee working in a plastic thermoforming plant was injured when the employee fell through a floor hole covering. Employee #1 was working alone at the time of the accident. Employee #1 was moving materials from one location to another, which required the employee to walk across the floor hole covering. The flooring hole covering was in place over a stair well that went to a grinder pit. Prior to the incident occurring, it was found that another employee, Employee #2, had parked a forklift near the floor hole covering. While doing so, Employee #2 hit the floor hole cover with the forks of the forklift, displacing the cover. Employee #2 attempted to fix the covering but did not ensure it was properly positioned. As Employee #1 went to move materials across the floor hole covering, Employee #1 fell 7 feet to the ground below. Employee #1 was driven to the emergency room by the employer and sustained three broken ribs on their left side, a punctured left lung, and a broken left scapula.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Serious | $9,239 | $5,543 | May 30, 2018 | Final |
Inspection 342036589 OPENED JAN 17, 2017Closed
Referral · Partial · Safety · 200 employees at the site · Closed Jul 5, 2017
N7660 Industrial Road, Portage, WI 53901 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Jan 6, 2017: Employee's right middle finger is amputated in a motorized c
At 11:45 p.m. on January 6, 2017, Employee #1 was working alone, performing product finishing duties at a plastic manufacturing plant. Employee #1 attempted to reach over a gravity based conveyor into a cooling tunnel to grab a plastic pallet, rather than wait for the pallet to come onto the gravity based conveyor. Employee #1, realizing that they could not reach the plastic pallet, began backing their hand out. Employee #1's hand made a downward motion, resulting in their glove being caught in the motorized conveyor belt of the cooling tunnel. Employee #1's right hand was pulled into the conveyor belt. The conveyor belt pushed Employee#1's hand up against a nip point between the side wall of the machine and the conveyor belt. The tip of Employee #1's right middle finger was crushed. Employee #1 was taken to the emergency room by a coworker, where a doctor determined the injury to be an amputation. amputation.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Serious | $8,149 | $4,849 | May 10, 2017 | Final |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 6 reports on file.
Jan 9, 2025, Portage: Hospitalization · fractures · hip joint(s)
An employee was banding a completed skid of plastic sheets on a 13-inch-tall, 8-foot x 8-foot platform. The employee fell from the platform to the concrete floor and suffered a broken left hip.
Mar 24, 2021, Portage: Amputation · amputations · finger(s), fingernail(s), unspecified
Two employees were removing a broken drive chain that weighted approximately 70 lbs. from a sprocket on a bottom plate motor. The injured employee's hand slipped from the oil on the chain and their right thumb was pinched between the chain and sprocket causing a partial thumb amputation.
Dec 13, 2020, Portage: Amputation · amputations · finger(s), fingernail(s), n.e.c.
On December 13, 2020, a press operator was making adjustments to the direction of a fan to cool the frames on the thermoforming press. The employee's left middle finger contacted the moving fan blades resulting in amputation to the first digit.
Jun 19, 2019, Portage: Amputation · amputations · fingertip(s)
An employee unscrewed a platen collar during set-up. The vibration of the thermoformer caused the platen to shift and fall on the employee's finger, amputating the tip (without bone loss).
Apr 24, 2018, Portage: Hospitalization · internal injuries to organs and blood vessels of the trunk · chest, except internal location of diseases or disorders
While transferring a plastic sheet onto a pallet, an employee fell 7 feet into a grinder pit due to an unfastened floor plate. The employee suffered three broken ribs, a punctured lung, and a broken scapula.
Jan 6, 2017, Portage: Amputation · amputations · fingertip(s)
An employee was retrieving a plastic part from inside a cooling tunnel when her finger became caught in a conveyor nip point, amputating her right middle fingertip.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.