OSHA SearchOSHA records by employer

Trinity Health Corporation: OSHA inspections and violations

Wilmington, Delaware · General Medical and Surgical Hospitals · NAICS 622110

3inspections
1citation items
$4,588current penalties
Jun 9, 2022last inspection

OSHA has inspected Trinity Health Corporation 3 times in Delaware since 2019.

The latest one began on Jun 9, 2022 to monitor an earlier case, in Wilmington.

Those inspections ended with 1 citation item: 1 serious.

Penalties were first proposed at $6,554 and now stand at $4,588, 30% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for health care employers since 2015 is $1,050, and Trinity Health Corporation averages $4,588 (1 cited inspection).

Trinity Health Corporation also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Trinity Health Corporation: OSHA citation items per year, 2019 to 2022
Citation items per year, by inspection date.

Delaware · latest 90 days of OSHA records

33employers cited

Get notified the morning OSHA posts each new citation in Delaware: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Delaware

Checking a subcontractor, a client or your own company? Watch Trinity Health Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346011323 OPENED JUN 9, 2022Closed

Monitoring · Partial · Health · 1,387 employees at the site · Closed Jun 13, 2022

701 N Clayton Street, Wilmington, DE 19805 · General Medical and Surgical Hospitals · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345129530 OPENED FEB 3, 2021Closed

Referral · Partial · Safety · 50 employees at the site · Closed Jul 30, 2021

701 N Clayton Street, Wilmington, DE 19805 · General Medical and Surgical Hospitals · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344401849 OPENED OCT 28, 2019Closed

Complaint · Partial · Health · 300 employees at the site · Closed May 26, 2020

701 N Clayton St, Wilmington, DE 19805 · General Medical and Surgical Hospitals · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$6,554$4,588Apr 27, 2020Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Wilmington site logged 30 recordable injuries or illnesses among about 718 workers: 5.2 per 100 full-time workers, against a median of 4.7 for its industry. Those cases cost 698 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
St. Francis Hospital-Wilmington-SFHC-DE
Wilmington · 2025
718 30125.24.7
Saint Francis Hospital
Wilmington · 2022
1,053 60327.74.7
LIFE at Saint Francis
Wilmington · 2020
116 11813.24.7
St. Francis Hospital
Wilmington · 2018
1,315 61206.54.7
Wilmington Life Facility
Wilmington · 2018
125 171418.32.2

Included with any plan: 10 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Feb 2, 2021, Wilmington: Hospitalization, amputation · amputations · finger(s), fingernail(s), unspecified

An employee was working to unjam the cable of a plumbing machine when his rubber glove got caught on the cable and caused an amputation to his right middle finger.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

Other general medical and surgical hospitals employers in Delaware

Alert subscribers get notified of each newly cited employer in Delaware the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.