OSHA SearchOSHA records by employer

Trinity Solar, Inc.: OSHA inspections and violations

Manahawkin, New Jersey · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

4inspections
2citation items
$4,000current penalties
Oct 4, 2022last inspection

Trinity Solar, Inc. has 4 OSHA inspections on record in New Jersey, the first in 2011.

OSHA's last visit started on Oct 4, 2022 after a fatality or catastrophe, in South Orange.

Across those inspections OSHA issued 2 citation items: 2 other-than-serious.

OSHA proposed $26,520 in penalties. After settlements and reviews the total is $4,000, down 85%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Trinity Solar, Inc. averages $4,000 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

It reported 1 severe injury to OSHA since 2015.

Trinity Solar, Inc.: OSHA citation items per year, 2011 to 2022
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

270employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Trinity Solar, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346261514 OPENED OCT 4, 2022Closed

Fatality or catastrophe · Partial · Safety · 2,000 employees at the site · Closed Apr 21, 2026

57 Riggs Place, South Orange, NJ 07079 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Oct 4, 2022 (fatal): Employee is killed from head injuries after fall off roof

At 12:45 p.m. on October 4, 2022, an employee was installing a solar panel 22-feet above the ground when he fell from the roof. The employee was not wearing fall protection and died from head trauma and multiple fractures.

No citations from this inspection.

Inspection 345106942 OPENED JAN 20, 2021Closed

Complaint · Partial · Safety · 10 employees at the site · Closed Feb 11, 2021

2211 Allenwood Road, Wall Township, NJ 07719 · Solar Electric Power Generation · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344022355 OPENED APR 29, 2019Closed

Referral · Complete · Safety · 300 employees at the site · Closed Sep 30, 2025

1512 51st St, North Bergen, NJ 07047 · Solar Electric Power Generation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.955(c) · Portable ladders and platforms
Other-than-serious$13,260$4,000Aug 7, 2019Final
Citation 1, item 3
29 CFR 1926.960(g)(1) · Working on or near exposed energized parts
Other-than-serious$13,260$0Aug 7, 2019Final

Inspection 315656272 OPENED JUN 30, 2011Closed

Planned · Complete · Safety · 300 employees at the site · Closed Aug 23, 2011

1321 E. Mallard Drive, Manahawkin, NJ 08050 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Dec 14, 2016, Wall Township: Hospitalization · puncture wounds, except gunshot wounds · hand(s), except finger(s)

An employee was nailing wooden boards against the rafters in an attic with an air-actuated framing nail gun when the recoil caused the gun to kick back. The gun hit the rafter behind him and then struck and penetrated the top of his left hand. The gun was in contact actuation mode at the time of the incident.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.955 · Portable ladders and platforms

29 CFR 1926.955(c)

(c) Conductive ladders. Portable metal ladders and other portable conductive ladders may not be used near exposed energized lines or equipment. However, in specialized high-voltage work, conductive ladders shall be used when the employer demonstrates that nonconductive ladders would present a greater hazard to employees than conductive ladders.

29 CFR 1926.960 · Working on or near exposed energized parts

29 CFR 1926.960(g)(1)

(g) Protection from flames and electric arcs—(1) Hazard assessment. The employer shall assess the workplace to identify employees exposed to hazards from flames or from electric arcs.

Other electrical contractors and other wiring installation contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.