OSHA SearchOSHA records by employer

Trismart Solar: OSHA inspections and violations

El Paso, Texas · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

3inspections
4citation items
$16,800current penalties
Aug 22, 2023last inspection

OSHA has inspected Trismart Solar 3 times in Texas since 2021.

The latest one began on Aug 22, 2023 after a fatality or catastrophe, in San Antonio.

Those inspections ended with 4 citation items: 4 other-than-serious.

Penalties were first proposed at $20,035 and now stand at $16,800, 16% lower after settlements or reviews.

Ladders in construction comes up most often in these citations: 2 items under 1926.1053.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Trismart Solar averages $8,400 (2 cited inspections).

1 inspection on this page followed a fatal incident.

The Wage and Hour Division has 1 case on it since 2015, with $32,515 in back wages owed to workers.

Trismart Solar: OSHA citation items per year, 2021 to 2023
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Trismart Solar and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346927080 OPENED AUG 22, 2023Closed

Fatality or catastrophe · Partial · Safety · 240 employees at the site · Closed Jan 17, 2024

104 Flintstone St., San Antonio, TX 78213 · Solar Electric Power Generation · OSHA's record · Phone and website on Google Maps

Incident on Aug 21, 2023 (fatal): Employee dies due to heat-related illness

At 2:00 p.m. on August 21, 2023, an employee was installing residential solar roof panels on a home. The employee felt symptoms of heat stress and went to the company van to cool down and rest in AC. The employee's body over-heated, and he died due to heat-related illness.

No citations from this inspection.

Inspection 346852809 OPENED JUL 24, 2023Closed

Unprogrammed other · Partial · Safety · 3 employees at the site · Closed Jan 12, 2024

216 Pembridge Place, Horizon City, TX 79928 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$5,122$5,000Aug 21, 2023Final
Citation 1, item 2
29 CFR 1926.1053(b)(22) · Ladders in construction
Other-than-serious$5,122$5,000Aug 21, 2023Final

Inspection 345215644 OPENED MAR 24, 2021Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 21, 2021

964 Crooked River Drive, El Paso, TX 79932 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Other-than-serious$8,953$6,000Jul 26, 2021Final
Citation 2, item 1
29 CFR 1926.503(c)(3) · Fall protection training in construction
Other-than-serious$838$800Jul 26, 2021Final

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Jun 1, 2022 to Jun 1, 2024
EL PASO
2423$32,515$0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(22)

(22) An employee shall not carry any object or load that could cause the employee to lose balance and fall.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.503 · Fall protection training in construction

Other electrical contractors and other wiring installation contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.