Triumph Interiors, LLC: OSHA inspections and violations

Atlanta, Georgia · Other Aircraft Parts and Auxiliary Equipment Manufacturing · NAICS 336413

1inspections
8citation items
$13,770current penalties
Jan 12, 2016last inspection

OSHA inspectors have visited Triumph Interiors, LLC in Georgia one time.

It opened on Jan 12, 2016 after a complaint, in Atlanta.

In all, OSHA issued 8 citation items: 2 serious and 6 other-than-serious.

The proposed penalties came to $26,100; today they stand at $13,770, 47% less.

The rule cited most here is 1910.106 (flammable liquids), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Triumph Interiors, LLC averages $13,770 across 1 cited inspection.

Triumph Interiors, LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

146employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Triumph Interiors, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341175503 OPENED JAN 12, 2016Closed

Complaint · Partial · Health · 68 employees at the site · Closed Mar 21, 2017

2001 Sullivan Rd, Atlanta, GA 30337 · Other Aircraft Parts and Auxiliary Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Other-than-serious$6,300$4,725Mar 9, 2016Final
Citation 1, item 2
29 CFR 1910.106(d)(4)(iii) · Flammable liquids
Other-than-serious$6,300$4,725Mar 9, 2016Final
Citation 1, item 3
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$4,500$2,700Mar 9, 2016Final
Citation 1, item 4
29 CFR 1910.124(g)(2) · General requirements for dipping and coating operations
Serious$2,700$1,620Mar 9, 2016Final
Citation 1, item 5
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$2,700$0Mar 9, 2016Final
Citation 1, item 6
29 CFR 1910.141(g)(2) · Sanitation
Other-than-serious$3,600$0Mar 9, 2016Final
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Mar 9, 2016Final
Citation 2, item 2
29 CFR 1910.305(c)(4) · Electrical wiring methods
Other-than-serious$0$0Mar 9, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iii)

(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.124 · General requirements for dipping and coating operations

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.305 · Electrical wiring methods