True Colors Painting, LLC: OSHA inspections and violations

Reading, Massachusetts · Painting and Wall Covering Contractors · NAICS 238320

1inspections
6citation items
$6,200current penalties
May 7, 2019last inspection

OSHA inspectors have visited True Colors Painting, LLC in Massachusetts one time.

It opened on May 7, 2019 as a planned inspection, in Reading.

In all, OSHA issued 6 citation items: 6 serious.

The proposed penalties came to $18,327; today they stand at $6,200, 66% less.

The rule cited most here is 1926.1053 (ladders in construction), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. True Colors Painting, LLC averages $6,200 across 1 cited inspection.

True Colors Painting, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

256employers cited

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch True Colors Painting, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344004957 OPENED MAY 7, 2019Closed

Planned · Partial · Safety · 4 employees at the site · Closed Apr 22, 2022

40 Pilgrim Road, Reading, MA 01867 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$3,978$1,600Jun 7, 2019Final
Citation 1, item 1b
29 CFR 1926.1053(b)(12) · Ladders in construction
Serious$0$0Jun 7, 2019Final
Citation 1, item 2a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,978$3,000Jun 7, 2019Final
Citation 1, item 2b
29 CFR 1926.1053(b)(6) · Ladders in construction
Serious$3,978$0Jun 7, 2019Final
Citation 1, item 3a
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$2,415$1,600Jun 7, 2019Final
Citation 1, item 3b
29 CFR 1926.1053(b)(5)(i) · Ladders in construction
Serious$3,978$0Jun 7, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(12)

(12) Ladders shall have nonconductive siderails if they are used where the employee or the ladder could contact exposed energized electrical equipment, except as provided in § 1926.955(b) and (c) of this part.

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.1053(b)(5)(i)

(5)(i) Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction

Other painting and wall covering contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.