OSHA SearchOSHA records by employer

True North Management Services LLC: OSHA inspections and violations

Burleson, Texas · Wireless Telecommunications Carriers (except Satellite) · NAICS 517312

1inspections
2citation items
$8,937current penalties
Jan 27, 2025last inspection

OSHA has inspected True North Management Services LLC once in Texas.

The inspection began on Jan 27, 2025 on a referral, in Burleson.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $14,895 and now stand at $8,937, 40% lower after settlements or reviews.

Telecommunications comes up most often in these citations: 2 items under 1910.268.

How that compares: the median penalty per cited inspection for media and telecom employers since 2015 is $1,800, and True North Management Services LLC averages $8,937 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

True North Management Services LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch True North Management Services LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348002155 OPENED JAN 27, 2025Closed

Referral · Partial · Safety · 6 employees at the site · Closed Sep 8, 2025

850 N Burleson Blvd, Burleson, TX 76028 · Wireless Telecommunications Carriers (except Satellite) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.268(b)(7) · Telecommunications
Serious$14,895$8,937Jun 27, 2025Final
Citation 1, item 1b
29 CFR 1910.268(e) · Telecommunications
Serious$0$0Jun 27, 2025Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jan 24, 2025, Burleson: Hospitalization · electrical burns any degree · trunk and other upper extremities

A crew was working to replace a beacon on a 150-foot monopole. Two employees of True North Management Services were working at the top of the cell tower when an arc flash occurred. One of them suffered second-degree burns to the arm and torso and was hospitalized.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.268 · Telecommunications

29 CFR 1910.268(b)(7)

(7) Approach distances to exposed energized overhead power lines and parts. The employer shall ensure that no employee approaches or takes any conductive object closer to any electrically energized overhead power lines and parts than prescribed in Table R-2, unless:

29 CFR 1910.268(e)

(e) Tools and personal protective equipment—Generally. Personal protective equipment, protective devices and special tools needed for the work of employees shall be provided and the employer shall ensure that they are used by employees. Before each day's use the employer shall ensure that these personal protective devices, tools, and equipment are carefully inspected by a competent person to ascertain that they are in good condition.

Other wireless telecommunications carriers (except satellite) employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.