Inspection 347888422 OPENED NOV 14, 2024Closed
205 Sw 24th St, Owatonna, MN 55060 · Hardware Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Truth Hardware Corp dba Amesburytruth - Paint 2 times in Minnesota since 2018.
The latest one began on Nov 14, 2024 as a planned inspection, in Owatonna.
Those inspections ended with 2 citation items: 2 serious.
Penalties were first proposed at $2,800 and now stand at $1,680, 40% lower after settlements or reviews.
Flammable liquids comes up most often in these citations: 2 items under 1910.106.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Truth Hardware Corp dba Amesburytruth - Paint averages $1,680 (1 cited inspection).
Minnesota · latest 90 days of OSHA records
375employers cited
Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Minnesota
Checking a subcontractor, a client or your own company? Watch Truth Hardware Corp dba Amesburytruth - Paint and get notified the morning OSHA posts a new citation for it.
Watch this company205 Sw 24th St, Owatonna, MN 55060 · Hardware Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
205 Sw 24th St, Owatonna, MN 55060 · Hardware Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2 29 CFR 1910.106(e)(6)(ii) · Flammable liquids |
Serious | $1,750 | $1,050 | Nov 29, 2018 | Final |
| Citation 1, item 3 29 CFR 1910.106(e)(9)(iii) · Flammable liquids |
Serious | $1,050 | $630 | Nov 29, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(e)(6)(ii)
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
29 CFR 1910.106(e)(9)(iii)
(iii) Waste and residue. Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.
Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.