OSHA has inspected TSM Corporation LLC 14 times in Michigan since 1995.
The latest one began on Sep 17, 2024 as a planned inspection, in Auburn Hills.
Those inspections ended with 59 citation items: 23 serious, 4 repeat and 32 other-than-serious.
Penalties were first proposed at $28,525 and now stand at $20,480, 28% lower after settlements or reviews.
Hazard communication comes up most often in these citations: 6 items under 1910.1200.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and TSM Corporation LLC averages $1,938 (4 cited inspections).
TSM Corporation LLC also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Michigan · latest 90 days of OSHA records
653employers cited
12 of them in the same industry
Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Auburn Hills site logged 21 recordable injuries or illnesses among about 185 workers: 15.1 per 100 full-time workers, against a median of 2.7 for its industry. Those cases cost 5 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
TSM Corporation LLC
Auburn Hills · 2025
185
21
2
15.1
2.7
Included with any plan: 1 more yearly log from these sites, back to 2024, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.
29 CFR 1910.106(e)(6)(i)
(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.
29 CFR 1910.106(e)(6)(ii)
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
29 CFR 1910.110 · Storage and handling of liquefied petroleum gases
Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.