OSHA SearchOSHA records by employer

Turley Stucco, Inc.: OSHA inspections and violations

Tulsa, Oklahoma · Siding Contractors · NAICS 238170

2inspections
7citation items
$5,920current penalties
Sep 1, 2015last inspection

Since 2014, OSHA inspectors have visited Turley Stucco, Inc. in Oklahoma 2 times.

The most recent inspection opened on Sep 1, 2015, in Tulsa.

In all, OSHA issued 7 citation items: 7 serious.

The proposed penalties came to $13,000; today they stand at $5,920, 54% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 7 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Turley Stucco, Inc. averages $4,000 across 1 cited inspection.

Turley Stucco, Inc.: OSHA citation items per year, 2014 to 2015
Citation items per year, by inspection date.

Oklahoma · latest 90 days of OSHA records

54employers cited

Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oklahoma

Checking a subcontractor, a client or your own company? Watch Turley Stucco, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340899624 OPENED SEP 1, 2015Closed

Programmed other · Partial · Safety · 30 employees at the site · Closed Mar 28, 2016

629 E. 3rd Street, Tulsa, OK 74147 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$4,900$4,000Oct 23, 2015Final
Citation 1, item 1b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$4,900$0Oct 23, 2015Final

Inspection 340070176 OPENED NOV 5, 2014Closed

Planned · Partial · Safety · 16 employees at the site · Closed Sep 29, 2015

6995 S. Mingo Rd., Tulsa, OK 74147 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,600$960Dec 19, 2014Final
Citation 1, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Dec 19, 2014Final
Citation 1, item 1c
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Dec 19, 2014Final
Citation 1, item 2a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,600$960Dec 19, 2014Final
Citation 1, item 2b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Dec 19, 2014Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

Other siding contractors employers in Oklahoma

Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.