OSHA SearchOSHA records by employer

Twin Metals, Inc.: OSHA inspections and violations

Burlington, Massachusetts · Roofing Contractors · NAICS 238160

3inspections
7citation items
$13,020current penalties
Aug 9, 2019last inspection

Since 2009, OSHA inspectors have visited Twin Metals, Inc. in Massachusetts 3 times.

The most recent inspection opened on Aug 9, 2019 as a planned inspection, in Gloucester.

In all, OSHA issued 7 citation items: 6 serious and 1 repeat.

The proposed penalties came to $27,174; today they stand at $13,020, 52% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Twin Metals, Inc. averages $11,520 across 1 cited inspection.

Twin Metals, Inc. also files yearly injury logs with OSHA, summarized below.

Twin Metals, Inc.: OSHA citation items per year, 2009 to 2019
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

247employers cited

49 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Twin Metals, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344223649 OPENED AUG 9, 2019Closed

Planned · Partial · Safety · 15 employees at the site · Closed Nov 8, 2021

33 Pleasant Street, Gloucester, MA 01931 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Serious$4,168$2,000Sep 24, 2019Final
Citation 1, item 2
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$4,168$2,000Sep 24, 2019Final
Citation 1, item 3
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$3,334$1,500Sep 24, 2019Final
Citation 1, item 4
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,168$2,000Sep 24, 2019Final
Citation 2, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$8,336$4,020Sep 24, 2019Final

Inspection 341033157 OPENED NOV 3, 2015Closed

Complaint · Complete · Safety · 17 employees at the site · Closed Nov 4, 2015

53 Baldwin Road, Billerica, MA 01821 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313768186 OPENED AUG 28, 2009Closed

Planned · Partial · Safety · 4 employees at the site · Closed Nov 27, 2009

29 Center Stereet, Burlington, MA 01803 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$1,500$750Nov 6, 2009Closed
Citation 1, item 2
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$1,500$750Nov 6, 2009Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2016, the Billerica site logged 3 recordable injuries or illnesses among about 15 workers: 21.1 per 100 full-time workers, against a median of 2.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Twin Metals Inc
Billerica · 2016
15 3021.12.8

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(i)

(5)(i) Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.