OSHA SearchOSHA records by employer

Twin Pines Home Improvements LLC: OSHA inspections and violations

Pewaukee, Wisconsin · Roofing Contractors · NAICS 238160

5inspections
9citation items
$8,911current penalties
Nov 9, 2021last inspection

Twin Pines Home Improvements LLC has 5 OSHA inspections on record in Wisconsin, the first in 2006.

OSHA's last visit started on Nov 9, 2021 as a planned inspection, in Mequon.

Across those inspections OSHA issued 9 citation items: 7 serious, 1 repeat and 1 other-than-serious.

OSHA proposed $15,572 in penalties. After settlements and reviews the total is $8,911, down 43%.

Most often, OSHA cited 1926.501, fall protection in construction (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Twin Pines Home Improvements LLC averages $3,844 over 2 cited inspections in that time.

Twin Pines Home Improvements LLC: OSHA citation items per year, 2006 to 2021
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

216employers cited

47 of them in the same industry

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Twin Pines Home Improvements LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345627533 OPENED NOV 9, 2021Closed

Planned · Partial · Safety · 3 employees at the site · Closed Dec 17, 2021

10603 N. Wood Crest Drive, Mequon, WI 53092 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,341$1,000Nov 26, 2021Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$7,022$4,600Nov 26, 2021Final

Inspection 345341747 OPENED JUN 3, 2021Closed

Planned · Partial · Safety · 8 employees at the site · Closed Jul 16, 2021

10710 N. Briarwood Ct., Mequon, WI 53092 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,984$2,089Jul 1, 2021Final

Inspection 309359685 OPENED MAY 12, 2007Closed

Planned · Partial · Safety · 7 employees at the site · Closed Nov 6, 2007

Seven Stones Rd. And Stepping Stone Way, Pewaukee, WI 53082 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.152(a)(1) · Flammable liquids
Other-than-serious$1,050$0May 18, 2007Closed
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$450$225May 18, 2007Closed
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$450$225May 18, 2007Closed

Inspection 122419393 OPENED APR 25, 2007Closed

Planned · Partial · Safety · 2 employees at the site · Closed Nov 6, 2007

3422-24 Saquoia Circle, Waukesha, WI 53188 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$600$300May 9, 2007Closed

Inspection 309353134 OPENED FEB 7, 2006Closed

Planned · Partial · Safety · 3 employees at the site · Closed Mar 7, 2006

W251 N4870 Belstone, Pewaukee, WI 53072 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$300$210Feb 16, 2006Closed
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$375$262Feb 16, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.152(a)(1)

(a) General requirements. (1) Only approved containers and portable tanks shall be used for storage and handling of flammable liquids. Approved safety cans or Department of Transportation approved containers shall be used for the handling and use of flammable liquids in quantities of 5 gallons or less, except that this shall not apply to those flammable liquid materials which are highly viscid (extremely hard to pour), which may be used and handled in original shipping containers. For quantities of one gallon or less, the original container may be used, for storage, use and handling of flammable liquids.

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.