Inspection 342402989 OPENED JUN 14, 2017Open
Pinfire Creek, Ammon, ID 83406 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Since 2017, OSHA inspectors have visited Two Brothers Construction and Renovation, Inc. in Idaho 2 times.
The most recent inspection opened on Jun 14, 2017 on a referral, in Ammon and is still open.
In all, OSHA issued 6 citation items: 6 serious.
The penalties, $26,619 in total, stand where OSHA first set them.
The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Two Brothers Construction and Renovation, Inc. averages $26,619 across 1 cited inspection.
Idaho · latest 90 days of OSHA records
55employers cited
8 of them in the same industry
Get notified the morning OSHA posts each new citation in Idaho: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Idaho
Checking a subcontractor, a client or your own company? Watch Two Brothers Construction and Renovation, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this companyPinfire Creek, Ammon, ID 83406 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Pinfire Creek, Ammon, ID 83406 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(a)(6) · Scaffolds, general requirements |
Serious | $8,873 | $8,873 | Jul 14, 2017 | Final |
| Citation 1, item 1b 29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements |
Serious | $0 | $0 | Jul 14, 2017 | Final |
| Citation 1, item 1c 29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements |
Serious | $0 | $0 | Jul 14, 2017 | Final |
| Citation 1, item 2a 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $8,873 | $8,873 | Jul 14, 2017 | Final |
| Citation 1, item 2b 29 CFR 1926.602(d) · Earthmovers and forklifts in construction |
Serious | $0 | $0 | Jul 14, 2017 | Final |
| Citation 1, item 3 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $8,873 | $8,873 | Jul 14, 2017 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(a)(6)
(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.
29 CFR 1926.451(c)(2)(iv)
(iv) Front-end loaders and similar pieces of equipment shall not be used to support scaffold platforms unless they have been specifically designed by the manufacturer for such use.
29 CFR 1926.451(c)(2)(v)
(v) Fork-lifts shall not be used to support scaffold platforms unless the entire platform is attached to the fork and the fork-lift is not moved horizontally while the platform is occupied.
Alert subscribers get notified of each newly cited employer in Idaho the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.