OSHA SearchOSHA records by employer

Two22 Brew, LLC: OSHA inspections and violations

Centennial, Colorado · Breweries · NAICS 312120

2inspections
4citation items
$3,500current penalties
Jul 31, 2019last inspection

Since 2019, OSHA inspectors have visited Two22 Brew, LLC in Colorado 2 times.

The most recent inspection opened on Jul 31, 2019 as a planned inspection, in Centennial.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $5,796; today they stand at $3,500, 40% less.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,874 penalty. Two22 Brew, LLC averages $3,500 across 1 cited inspection.

Two22 Brew, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Two22 Brew, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344197280 OPENED JUL 31, 2019Closed

Planned · Complete · Safety · 11 employees at the site · Closed Jan 7, 2020

4550 S Reservoir Road, Centennial, CO 80015 · Breweries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.146(c)(3) · Permit-required confined spaces
Serious$3,220$1,955Aug 19, 2019Final
Citation 1, item 2a
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$2,576$1,545Aug 19, 2019Final
Citation 1, item 2b
29 CFR 1926.403(b)(1)(i) · Electrical equipment on job sites
Serious$0$0Aug 19, 2019Final
Citation 1, item 2c
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$0$0Aug 19, 2019Final

Inspection 343965331 OPENED APR 29, 2019Closed

Planned · No inspection · Health · 11 employees at the site · Closed Apr 30, 2019

4550 S. Reservoir Road, Centennial, CO 80015 · Breweries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.146(c)(3)

(3) If the employer decides that its employees will not enter permit spaces, the employer shall take effective measures to prevent its employees from entering the permit spaces and shall comply with paragraphs (c)(1), (c)(2), (c)(6), and (c)(8) of this section.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(2)(i)

(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)(i)

(i) Suitability for installation and use in conformity with the provisions of this subpart. Suitability of equipment for an identified purpose may be evidenced by listing, labeling, or certification for that identified purpose.

29 CFR 1926.404 · Ground-fault protection on job sites

Other breweries employers in Colorado

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.