U.S. Tsubaki Power Transmission, LLC: OSHA inspections and violations
Holyoke, Massachusetts · All Other Miscellaneous Fabricated Metal Product Manufacturing · NAICS 332999
1inspections
2citation items
$7,375current penalties
Jun 15, 2021last inspection
U.S. Tsubaki Power Transmission, LLC has one OSHA inspection on record in Massachusetts.
OSHA opened it on Jun 15, 2021 on a referral, in Holyoke.
From that inspection OSHA issued 2 citation items: 1 serious and 1 other-than-serious.
OSHA proposed $12,288 in penalties. After settlements and reviews the total is $7,375, down 40%.
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. U.S. Tsubaki Power Transmission, LLC averages $7,375 over 1 cited inspection in that time.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Massachusetts · latest 90 days of OSHA records
266employers cited
Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch U.S. Tsubaki Power Transmission, LLC and get notified the morning OSHA posts a new citation for it.
OSHA records show U.S. Tsubaki Power Transmission, LLC at 2 sites in 2 states. Together they've had 2 inspections and $7,375 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
Incident on Jun 11, 2021: Employee sustains fingertip amputation while operating mecha
At 9:45 a.m. on June 11, 2021, Employee #1 was operating a mechanical power press to press chain links. The machine guarding and safety devices designed to prevent operator injury were deficient. The two-hand trip control allowed hand exposure during operation, the light curtains did not prevent access to the danger zone, and the automatic guard failed to prevent the operator from reaching around into the hazard area. The press's safety system and operational programming allowed a delayed but automatic cycling of the ram after the trip was triggered and all safety devices sent a safe signal back to the computer. The employee sustained a fingertip amputation and was treated without hospitalization.
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
(c) Safeguarding the point of operation—(1) General requirements. (i) It shall be the responsibility of the employer to provide and insure the usage of “point of operation guards” or properly applied and adjusted point of operation devices on every operation performed on a mechanical power press. See Table O-10.
Other all other miscellaneous fabricated metal product manufacturing employers in Massachusetts
Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.