OSHA SearchOSHA records by employer

Ugly Brothers, LLC: OSHA inspections and violations

Carson, California · Automotive Body, Paint, and Interior Repair and Maintenance · NAICS 811121

1inspections
5citation items
$3,230current penalties
Jul 17, 2020last inspection

Ugly Brothers, LLC has one OSHA inspection on record in California.

OSHA opened it on Jul 17, 2020 after an accident, in Carson.

From that inspection OSHA issued 5 citation items: 1 serious and 4 other-than-serious.

OSHA proposed $14,730 in penalties. After settlements and reviews the total is $3,230, down 78%.

For context, across all repair and personal services employers the median penalty per cited inspection since 2015 is $1,200. Ugly Brothers, LLC averages $3,230 over 1 cited inspection in that time.

Ugly Brothers, LLC: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

California · latest 90 days of OSHA records

1,134employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in California

Checking a subcontractor, a client or your own company? Watch Ugly Brothers, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344841267 OPENED JUL 17, 2020Closed

Accident · Partial · Safety · 9 employees at the site · Closed Nov 20, 2024

21222 S Wilmington Ave, Carson, CA 90810 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Incident on May 26, 2020: Employee sustains burns to arms and hands from flash fire

At 9:00 a.m. on May 26, 2020, an employee working as an automotive technician for an autobody shop was attempting to vent compressed natural gas tanks situated on top of a city bus. The employee was preparing to replace potentially defective pressure relief devices (PRD) as a part of a recall retrofit. The employee did not ground the bus at its grounding point. The employee also did not defuel the bus utilizing the defueling instructions on the bus. The employee attempted to heat up the PRDs using a heat gun to a temperature that would cause the PRDs to activate and vent the tanks. While performing this task, a sudden flash fire occurred, burning the employee and destroying the bus, as well as the two busses parked next to it. The most likely contributing factors to this accident were, lack of proper grounding, lack of proper procedures for defueling the bus, and hazardous method employed to pop off potentially defective PRDs to vent the tanks quickly. The employee sustained 2nd and 3rd degree burns to his arms and hands and was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 3203(A)
Other-than-serious$260$260Jun 30, 2021Final
Citation 1, item 2
29 CFR 3380(F)(2)
Other-than-serious$260$260Jun 30, 2021Final
Citation 1, item 3
29 CFR 3383(A)
Other-than-serious$260$0Jun 30, 2021Final
Citation 2, item 1
29 CFR 3329(D)
Other-than-serious$3,150$350Jun 30, 2021Final
Citation 3, item 1
29 CFR 5416(C)
Serious$10,800$2,360Jun 30, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

Other automotive body, paint, and interior repair and maintenance employers in California

Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.