OSHA SearchOSHA records by employer

UH - Maui College: OSHA inspections and violations

Kahului, Hawaii · Colleges, Universities, and Professional Schools · NAICS 611310

1inspections
3citation items
$5,803current penalties
Aug 12, 2021last inspection

UH - Maui College has one OSHA inspection on record in Hawaii.

OSHA opened it on Aug 12, 2021 as a planned inspection, in Kahului.

From that inspection OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

OSHA proposed $8,290 in penalties. After settlements and reviews the total is $5,803, down 30%.

Most often, OSHA cited 1910.253, gas welding and cutting (2 items).

For context, across all education employers the median penalty per cited inspection since 2015 is $0. UH - Maui College averages $5,803 over 1 cited inspection in that time.

UH - Maui College: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Hawaii · latest 90 days of OSHA records

63employers cited

Get notified the morning OSHA posts each new citation in Hawaii: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Hawaii

Checking a subcontractor, a client or your own company? Watch UH - Maui College and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345485981 OPENED AUG 12, 2021Closed

Planned · Complete · Safety · State government · 861 employees at the site · Closed Jan 10, 2022

310 W. Kaahumanu Ave. Ho' Okipa Bldg #106, Kahului, HI 96732 · Colleges, Universities, and Professional Schools · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$8,290$5,803Nov 5, 2021Final
Citation 2, item 1a
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Other-than-serious$0$0Nov 5, 2021Final
Citation 2, item 1b
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0Nov 5, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(2)(ii)

(ii) Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.

29 CFR 1910.253(b)(4)(iii)

(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.28(b)(1)(i)

(b) Protection from fall hazards—(1) Unprotected sides and edges. (i) Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the following:

Other colleges, universities, and professional schools employers in Hawaii

Alert subscribers get notified of each newly cited employer in Hawaii the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.