OSHA SearchOSHA records by employer

Ultimate Development Inc.: OSHA inspections and violations

Center Valley, Pennsylvania · Framing Contractors · NAICS 238130

4inspections
19citation items
$93,898current penalties
Apr 21, 2017last inspection

Since 2016, OSHA inspectors have visited Ultimate Development Inc. in Pennsylvania 4 times.

The most recent inspection opened on Apr 21, 2017 on a referral, in Center Valley.

In all, OSHA issued 19 citation items: 13 serious and 6 repeat.

The penalties, $93,898 in total, stand where OSHA first set them.

The rule cited most here is 1926.1053 (ladders in construction), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,078 penalty. Ultimate Development Inc. averages $23,474 across 4 cited inspections.

Ultimate Development Inc.: OSHA citation items per year, 2016 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Ultimate Development Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342269511 OPENED APR 21, 2017Closed

Referral · Partial · Safety · 21 employees at the site · Closed Apr 11, 2023

Lot 16 Cumorah Ave., Center Valley, PA 18034 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$4,780$4,780Jun 26, 2017Final
Citation 1, item 2
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$4,780$4,780Jun 26, 2017Final
Citation 2, item 1
29 CFR 1926.28(a) · Personal protective equipment
Repeat$9,560$9,560Jun 26, 2017Final
Citation 2, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$27,885$27,885Jun 26, 2017Final
Citation 2, item 3a
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Repeat$6,374$6,374Jun 26, 2017Final
Citation 2, item 3b
29 CFR 1926.1053(b)(13) · Ladders in construction
Repeat$0$0Jun 26, 2017Final
Citation 2, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Repeat$11,154$11,154Jun 26, 2017Final

Inspection 342240132 OPENED APR 10, 2017Closed

Planned · Partial · Safety · 6 employees at the site · Closed May 16, 2023

7717 Francis Street, Swissvale, PA 15218 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$4,780$4,780Jun 2, 2017Final

Inspection 341840577 OPENED OCT 13, 2016Closed

Planned · Partial · Safety · 3 employees at the site · Closed Dec 2, 2019

Lot 9 Dickinson Lane, Plymouth Meeting, PA 19462 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,741$3,741Oct 27, 2016Final
Citation 1, item 2
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$3,741$3,741Oct 27, 2016Final

Inspection 341756070 OPENED AUG 31, 2016Closed

Referral · Partial · Safety · 6 employees at the site · Closed Dec 13, 2019

Lot 13, Center Valley, PA 18034 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.28(a) · Personal protective equipment
Serious$3,207$3,207Oct 3, 2016Final
Citation 1, item 2
29 CFR 1926.150(c)(1)(vi) · Fire protection
Serious$2,138$2,138Oct 3, 2016Final
Citation 1, item 3a
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$2,672$2,672Oct 3, 2016Final
Citation 1, item 3b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Oct 3, 2016Final
Citation 1, item 4
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,741$3,741Oct 3, 2016Final
Citation 1, item 5a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,207$3,207Oct 3, 2016Final
Citation 1, item 5b
29 CFR 1926.1053(b)(5)(i) · Ladders in construction
Serious$0$0Oct 3, 2016Final
Citation 1, item 5c
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Oct 3, 2016Final
Citation 1, item 6
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$2,138$2,138Oct 3, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.150 · Fire protection

29 CFR 1926.25 · Housekeeping

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Pennsylvania

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.