OSHA SearchOSHA records by employer

Underwood Electric, Inc.: OSHA inspections and violations

Presque Isle, Maine · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

4inspections
6citation items
$35,700current penalties
Jan 13, 2015last inspection

Underwood Electric, Inc. has 4 OSHA inspections on record in Maine, the first in 2008.

OSHA's last visit started on Jan 13, 2015 on a referral, in Corinth.

Across those inspections OSHA issued 6 citation items: 3 serious, 1 willful and 2 other-than-serious.

OSHA proposed $44,100 in penalties. After settlements and reviews the total is $35,700, down 19%.

Most often, OSHA cited 1926.405, job-site wiring (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Underwood Electric, Inc. averages $33,600 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Underwood Electric, Inc.: OSHA citation items per year, 2008 to 2015
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

34employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch Underwood Electric, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340177971 OPENED JAN 13, 2015Closed

Referral · Complete · Safety · 2 employees at the site · Closed Jul 14, 2015

74 Hob Road, Corinth, ME 04427 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 8, 2015: Employee sustains back and head injuries in fall from aerial

At 10:00 a.m. on January 8, 2015, Employee #1 and a coworker, employed by Underwood Electric, Inc., were working at the construction site for a single-story manufacturing plant. They were engaged in plumbing/electrical work. Using an aerial lift, Employee #1 transported coworker to the top of the burner. The aerial lift became entangled with the frame of the burner. Employee #1 was ejected from the aerial lift's basket and he fell 20 feet. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for a fractured back and a head laceration. The subsequent investigation determined that Employee #1 was not wearing fall protection.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Willful$42,000$33,600Jul 2, 2015Final

Inspection 313070377 OPENED APR 23, 2009Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed May 13, 2009

64 Station Road (inland Fisheries & Wildlife), Ashland, ME 04732 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$800$800Apr 30, 2009Closed
Citation 2, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Other-than-serious$0$0Apr 30, 2009Closed

Inspection 313070203 OPENED APR 16, 2009Closed

Unprogrammed related · Complete · Safety · 3 employees at the site · Closed May 4, 2009

North Street, Presque Isle, ME 04769 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.417(b) · Lockout and tagging of circuits
Serious$1,000$1,000Apr 28, 2009Closed
Citation 2, item 1
29 CFR 1926.403(h) · Electrical equipment on job sites
Other-than-serious$0$0Apr 28, 2009Closed

Inspection 312516404 OPENED SEP 17, 2008Closed

Unprogrammed other · Complete · Safety · 22 employees at the site · Closed Oct 9, 2008

University Of Maine, Presque Isle, ME 04769 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$300$300Sep 29, 2008Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jan 8, 2015, Corinth: Hospitalization · traumatic injuries and disorders, unspecified · nonclassifiable

Around 10 am yesterday morning, an employee fell from an aerial lift while working on a pellet unit.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)(ii)

(ii) Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(h)

(h) Identification of disconnecting means and circuits. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. These markings shall be of sufficient durability to withstand the environment involved.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

29 CFR 1926.417 · Lockout and tagging of circuits

29 CFR 1926.453 · Aerial lifts

Other electrical contractors and other wiring installation contractors employers in Maine

Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.