OSHA SearchOSHA records by employer

United Mechanical (GU) LLC: OSHA inspections and violations

Barrigada, Guam · Commercial and Institutional Building Construction · NAICS 236220

1inspections
4citation items
$18,827current penalties
Jan 20, 2026last inspection

United Mechanical (GU) LLC has one OSHA inspection on record in Guam.

OSHA opened it on Jan 20, 2026, in Barrigada, and the case has not closed yet.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $26,896 in penalties. After settlements and reviews the total is $18,827, down 30%.

Most often, OSHA cited 1926.1053, ladders in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. United Mechanical (GU) LLC averages $18,827 over 1 cited inspection in that time.

United Mechanical (GU) LLC: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Guam · latest 90 days of OSHA records

6employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Guam: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Guam

Checking a subcontractor, a client or your own company? Watch United Mechanical (GU) LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348706995 OPENED JAN 20, 2026Open

Unprogrammed other · Complete · Safety · 88 employees at the site · Open

Uog Weri Building, Barrigada, GU 96921 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$8,276$5,793Apr 1, 2026Final
Citation 1, item 2
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$7,035$4,924Apr 1, 2026Final
Citation 1, item 3a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$11,585$8,110Apr 1, 2026Final
Citation 1, item 3b
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$0$0Apr 1, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.501 · Fall protection in construction

Other commercial and institutional building construction employers in Guam

Alert subscribers get notified of each newly cited employer in Guam the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.