OSHA SearchOSHA records by employer

United Metal Products, Inc.: OSHA inspections and violations

Phoenix, Arizona · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · NAICS 333415

8inspections
33citation items
$1,047current penalties
Feb 16, 2016last inspection

OSHA has inspected United Metal Products, Inc. 8 times in Arizona since 1989.

The latest one began on Feb 16, 2016 as a planned inspection, in Tempe.

Those inspections ended with 33 citation items: 4 serious and 29 other-than-serious.

Penalties were first proposed at $1,550 and now stand at $1,047, 32% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 5 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and United Metal Products, Inc. averages $375 (2 cited inspections).

United Metal Products, Inc.: OSHA citation items per year, 1989 to 2016
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

84employers cited

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch United Metal Products, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341282978 OPENED FEB 16, 2016Closed

Planned · Complete · Health · 80 employees at the site · Closed Jun 23, 2016

1920 E Broadway Rd, Tempe, AZ 85282 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(b)(5) · Overhead and gantry cranes
Other-than-serious$0$0Jun 1, 2016Final

Inspection 341283133 OPENED FEB 16, 2016Closed

Planned · Complete · Health · 80 employees at the site · Closed Sep 29, 2016

1920 E Encanto Dr, Tempe, AZ 85281 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$750$750Jun 1, 2016Final
Citation 2, item 1
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Jun 1, 2016Final
Citation 2, item 2
29 CFR 1910.134(i)(5)(iv) · Respiratory protection
Other-than-serious$0$0Jun 1, 2016Final

Inspection 126988203 OPENED MAR 30, 1998Closed

Planned · Complete · Health · 48 employees at the site · Closed Jun 11, 1998

1920 E. Encanto Dr., Tempe, AZ 85251 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$250$187May 6, 1998Closed

Inspection 108184128 OPENED SEP 5, 1990Closed

Planned · Complete · Health · 20 employees at the site · Closed Sep 10, 1990

127 S 43rd St, Phoenix, AZ 85034 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 108174624 OPENED JAN 25, 1990Closed

Follow-up · Partial · Safety · 22 employees at the site · Closed Jan 30, 1990

127 S 43rd St, Phoenix, AZ 85034 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 108174475 OPENED DEC 5, 1989Closed

Follow-up · Partial · Safety · 22 employees at the site · Closed Jan 30, 1990

127 S 43rd St, Phoenix, AZ 85034 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 108199332 OPENED AUG 14, 1989Closed

Referral · Partial · Health · 25 employees at the site · Closed Aug 18, 1989

127 S 43rd St, Phoenix, AZ 85034 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 108166042 OPENED JUN 9, 1989Closed

Planned · Complete · Safety · 25 employees at the site · Closed Jan 30, 1990

127 S 43rd St, Phoenix, AZ 85034 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 230403 A
Serious$300$10Aug 22, 1989Closed
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$250$100Aug 22, 1989Closed
Citation 2, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 2a
29 CFR 1910.106(d)(3)(iii) · Flammable liquids
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 2b
29 CFR 1910.106(d)(3)(ii) · Flammable liquids
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 3
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 4
29 CFR 1910.212(a)(2) · Machine guarding
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 6
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 7
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 8
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 9
29 CFR 1910.217(b)(4)(i) · Mechanical power presses
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 10
29 CFR 1910.217(b)(8)(i) · Mechanical power presses
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 11
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 12
29 CFR 1910.217(e)(1)(ii) · Mechanical power presses
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 13
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 14
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 15
29 CFR 1910.252(c)(2)(v) · Welding fire safety
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 16
29 CFR 1910.252(c)(2)(vi) · Welding fire safety
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 17
29 CFR 1910.252(c)(6) · Welding fire safety
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 18
29 CFR 1910.252(e)(2)(iii) · Welding fire safety
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 19a
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 19b
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 20
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 21
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 22
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 23
29 CFR 1910.1200(f)(4)(i) · Hazard communication
Other-than-serious$0$0Aug 22, 1989Closed
Citation 2, item 24
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Aug 22, 1989Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(3)(ii)

(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”

29 CFR 1910.106(d)(3)(iii)

(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.305 · Electrical wiring methods

Other air-conditioning and warm air heating equipment and commercial and industrial refrigeration equipment manufacturing employers in Arizona

Alert subscribers get notified of each newly cited employer in Arizona the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.