OSHA SearchOSHA records by employer

United Signs & Signals, Inc.: OSHA inspections and violations

Orlando, Florida · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

4inspections
6citation items
$197,157current penalties
Dec 7, 2023last inspection

OSHA has inspected United Signs & Signals, Inc. 4 times in Florida since 2001.

The latest one began on Dec 7, 2023 to follow up on an earlier case, in Orlando.

Those inspections ended with 6 citation items: 4 serious, 1 willful and 1 other-than-serious.

Penalties were first proposed at $248,766 and now stand at $197,157, 21% lower after settlements or reviews.

Excavations comes up most often in these citations: 2 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and United Signs & Signals, Inc. averages $189,317 (1 cited inspection).

1 inspection on this page followed a fatal incident.

United Signs & Signals, Inc.: OSHA citation items per year, 2001 to 2023
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

315employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch United Signs & Signals, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347149007 OPENED DEC 7, 2023Closed

Follow-up · Partial · Safety · 6 employees at the site · Closed Dec 21, 2023

Sr 528 Eastbound Past Mco 1/4 Mile From Exit 12, Orlando, FL 32822 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345172365 OPENED MAR 2, 2021Closed

Fatality or catastrophe · Complete · Safety · 65 employees at the site · Closed Aug 16, 2023

Sr 528 Eastbound Past Mco 1/4 Mile From Exit 12, Orlando, FL 32822 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Mar 2, 2021 (fatal): Employee is killed by electrocution

At 1:55 p.m. on March 2, 2021, an employee worked in an excavation to splice existing streetlight wires. At some point, the tool used for the splice made contact with a live 480-volt wire. The employee was killed by electrocution.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$9,557$9,557Jul 30, 2021Final
Citation 1, item 2
29 CFR 1926.651(h)(1) · Excavations
Other-than-serious$9,557$5,000Jul 30, 2021Final
Citation 2, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$109,226$87,380Jul 30, 2021Final
Citation 2, item 2
29 CFR 1926.652(a)(1) · Trench protection
Willful$109,226$87,380Jul 30, 2021Final

Inspection 339543035 OPENED JAN 10, 2014Closed

Fatality or catastrophe · Complete · Safety · 6 employees at the site · Closed Jul 30, 2014

State Rd. 50 & Us Hwy 19, Weeki Wachee, FL 34614 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1408(a)(2) · Power line safety (up to 350 kV)—equipment operations
Serious$4,900$3,430Jul 2, 2014Final
Citation 1, item 2
29 CFR 1926.1425(c)(2) · Keeping clear of the load
Serious$6,300$4,410Jul 2, 2014Final

Inspection 303986939 OPENED OCT 30, 2001Closed

Unprogrammed related · Complete · Safety · 6 employees at the site · Closed Feb 22, 2002

Hwy 17/92 And North Pine Meadows Drive, De Bary, FL 32713 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1408 · Power line safety (up to 350 kV)—equipment operations

29 CFR 1926.1408(a)(2)

(2) Determine if any part of the equipment, load line or load (including rigging and lifting accessories), if operated up to the equipment's maximum working radius in the work zone, could get closer than 20 feet to a power line. If so, the employer must meet the requirements in Option (1), Option (2), or Option (3) of this section, as follows:

29 CFR 1926.1425 · Keeping clear of the load

29 CFR 1926.1425(c)(2)

(2) Hooks with self-closing latches or their equivalent must be used. Exception: “J” hooks are permitted to be used for setting wooden trusses.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other electrical contractors and other wiring installation contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.