OSHA SearchOSHA records by employer

United Structures Inc.: OSHA inspections and violations

Ladysmith, Wisconsin · Structural Steel and Precast Concrete Contractors · NAICS 238120

5inspections
13citation items
$9,216current penalties
Feb 15, 2022last inspection

Since 1995, OSHA inspectors have visited United Structures Inc. in Wisconsin 5 times.

The most recent inspection opened on Feb 15, 2022 as a planned inspection, in Mosinee.

In all, OSHA issued 13 citation items: 13 serious.

The proposed penalties came to $14,913; today they stand at $9,216, 38% less.

The rule cited most here is 1926.59 (hazard communication), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. United Structures Inc. averages $1,502 across 2 cited inspections.

United Structures Inc.: OSHA citation items per year, 1995 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites United Structures Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345788566 OPENED FEB 15, 2022Closed

Planned · Partial · Safety · 4 employees at the site · Closed May 6, 2022

880 South View Drive, Mosinee, WI 54455 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$3,108$1,554Feb 25, 2022Final

Inspection 344193842 OPENED JUL 30, 2019Closed

Planned · Partial · Safety · 5 employees at the site · Closed Feb 11, 2020

4600 Block Of 154th Ave, Marathon, WI 54448 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.760(a)(1) · Fall protection
Serious$2,415$1,449Sep 18, 2019Final
Citation 1, item 1b
29 CFR 1926.761(b) · Training
Serious$0$0Sep 18, 2019Final

Inspection 331103200 OPENED DEC 13, 2011Closed

Referral · Partial · Safety · 20 employees at the site · Closed Feb 1, 2012

Lincoln County Tech College Fire Tech Building, Merrill, WI 54452 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$2,040$1,428Jan 17, 2012Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,550$1,785Jan 17, 2012Final

Inspection 309836120 OPENED SEP 19, 2006Closed

Planned · Partial · Safety · 12 employees at the site · Closed Oct 31, 2006

1424 Schofield, Schofield, WI 54476 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$1,500$1,050Oct 18, 2006Closed
Citation 1, item 2
29 CFR 1926.760(b)(3) · Fall protection
Serious$1,500$1,050Oct 18, 2006Closed

Inspection 106049372 OPENED FEB 9, 1995Closed

Planned · Partial · Safety · 5 employees at the site · Closed Mar 1, 1995

400 West 9th St. S, Ladysmith, WI 54848 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.59(e)(4) · Hazard communication
Serious$450$225Feb 15, 1995Closed
Citation 1, item 1b
29 CFR 1926.59(g)(8) · Hazard communication
Serious$0$0Feb 15, 1995Closed
Citation 1, item 1c
29 CFR 1926.59(h) · Hazard communication
Serious$0$0Feb 15, 1995Closed
Citation 1, item 2a
29 CFR 1926.404(a)(2) · Ground-fault protection on job sites
Serious$750$375Feb 15, 1995Closed
Citation 1, item 2b
29 CFR 1926.404(b)(1)(iii) · Ground-fault protection on job sites
Serious$0$0Feb 15, 1995Closed
Citation 1, item 3 Serious$600$300Feb 15, 1995Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(a)(2)

(2) Polarity of connections. No grounded conductor shall be attached to any terminal or lead so as to reverse designated polarity.

29 CFR 1926.404(b)(1)(iii)

(iii) Assured equipment grounding conductor program. The employer shall establish and implement an assured equipment grounding conductor program on construction sites covering all cord sets, receptacles which are not a part of the building or structure, and equipment connected by cord and plug which are available for use or used by employees. This program shall comply with the following minimum requirements:

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(e)(1)

(e) Cords and cables. (1) Worn or frayed electric cords or cables shall not be used.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.556

29 CFR 1926.59 · Hazard communication

29 CFR 1926.760 · Fall protection

29 CFR 1926.761 · Training